TEX3500LCD
17
/ 54
USer Manual
Rev. 2.0 - 27/01/20
Don’t forget to equip yourself with a 7/8“ 50 Ohm RF cable for the connection
between the Antenna and the device; the part that goes towards the device must
be equipped with a 7/8“ type connector.
Connect the RF output of the transmitter to an antenna cable or to a dummy load
capable of dissipating the power generated by the amplifier. To begin with, set
exciter to minimum output power and switch if off.
Connect the amplifier INTERLOCK OUT output to the matching INTERLOCK IN
input fitted on all R.V.R. Elettronica exciters as standard; if your exciter is a different
brand, identify an equivalent input.
Connect the RF output to an adequately rated dummy load or to the antenna.
WARNING: To avoid electrical shock and electrocution, never touch the RF
output connector when the equipment is switched on and no dummy load
is connected.
Ensure that the POWER switch on the front panel of
TEX3500LCD
is set to
“
OFF
”.
Connect the mains power cable to the MAINS connector on the rear panel.
Note:
the mains must be equipped with adequate earth connection properly
connected to the equipment. This is a pre-requisite for ensuring operator safety
and correct operation.
Connect the audio and RDS/SCA signals from user’s sources to the transmitter
input connectors.
5.1.5 First power-on and setup
Perform this procedure upon first power-up and each time you make changes to
the configuration of the transmitter this component is integrated into.
Note :
Standard factory settings are RF output power off (
Pwr OFF
) and regulated
output power set to upper limit (unless otherwise specified by customer).
5.1.5.1
Power-on
When you have performed all of the connections described in the previous
paragraph, power on the transmitter using the suitable power switch on the front
panel.