ii
User Manual
Rev. 2.0 - 27/01/20
TEX3500LCD
Connector
XLR F
Type
Balanced
Impedance
Ohm
10 k or 600
Selectable by rear panel dip switches
Input Level /Adjust
dBu
-13 to +13
continuosly variable
Connector
XLR F
Type
Balanced
Impedance
Ohm
10 k or 600
Selectable by rear panel dip switches
Input Level
dBu
-13 to +13
continuosly variable
Connector
BNC
Type
unbalanced
Impedance
Ohm
10 k or 50
Selectable by rear panel dip switches
Input Level / Adjust
dBu
*-13 to +13
for 75 KHz FM, externally adjustable
Connector
2 x BNC
Type
unbalanced
Impedance
Ohm
10 k
Input Level / Adjust
dBu
*-8 to +13
for 7,5 KHz FM, externally adjustable
Connector
XLR F
Type
Balanced
Impedance
Ohm
110
Input Level / Adjust
dBfs
0 to -10
for 7,5 KHz FM, externally adjustable
Connector
TOS-LINk
Type
Optical
Connector
7/8" EIA
Impedance
Ohm
50
Connector
BNC
Impedance
Ohm
50
Output Level
dB
approx. -60
Referred to the RF output
Connector
BNC
For RDS and isofrequency synchronizing purpose
Impedance
Ohm
>5 k
Output Level
Vpp
1
Interlock
Connector
2 x BNC
Input and output for remote power inhibition (short is RF off)
Service
Connector
DB9 F
Factory reserved for firmware program
Remote Interface
Connector
DB15F
IIC + 5 analog / digital inputs, 5 analog / digital outputs
FUSES
On Mains
3 External F 10 T - 6 x 30 mm
On services
On PA Supply
4 Internal F 32 A 10 x 38 mm
On Driver Supply
Input device
4 pushbutton
Display
Alphanumerical LCD - 2 x 16
10
FWD fold
For P.A. A.G.C. purpose, min 0,5 Vcc
2
REF fold
For P.A. A.G.C. purpose, min 0,5 Vcc
14
RF ON
15
RF OFF
Close to GND
1
Interlock
for remote power inhibition (short is RF off)
6
FWD
max 5 Vcc
13
REF
max 5 Vcc
5
VPA
max 5 Vcc
12
IPA
max 5 Vcc
Open Collector
7
Power Good
open collector
Left / Mono
AUDIO INPUTS
TELEMETRY / TELECONTROL
Right
MPX
SCA/RDS
AES/EBU
(optional)
TOS/Link
(optional)
OUTPUTS
RF Output
RF Monitor
Pilot output
AUXILIARY CONNECTIONS
HUMAN INTERFACES
Remote connector inputs
Analogical level
Pulse to GND
Remote connector outputs
Analogical level