4.4 Rear Panel Description
Figure 4.2
[1] AIR FLOW
Air flow for the forced ventilation.
[2] EXT REF 10MHz
Reserved for future implementations.
[3] PILOT ADJ
Pilot tone adjustment trimmer.
[4] PHASE ADJ
Phase adjustment trimmer.
[5] 19 kHz PILOT OUT
BNC output for the 19 kHz pilot tone. This can be used for
external devices (e.g. RDS coders) synchronization.
[6] PREEMPHASIS
Dip-switch to set the preenphasys at 50 or 75 μs. The
preenphasys setting is relevant only for the Left and Right
inputs in stereo mode and for the mono input in mono mode,
while MPX input is unaffected by this setting.
[7] MODE/MPX IMP
Dip-switch to set the operation mode (STEREO or MONO)
and the MPX input impedance, 50Ω or 10kΩ.
[8] SCA2
BNC connector, SCA2 unbalanced input.
[9] SCA1/RDS
BNC connector, SCA1/RDS unbalanced input.
[10] MPX
BNC connector, MPX unbalanced input.
[11] SCA2 ADJ
Adjustment trimmer for SCA2 input.
[12] MPX ADJ
Adjustment trimmer for MPX input.
[13] SCA1/RDS ADJ
Adjustment trimmer for SCA1/RDS input.
[14] RIGHT ADJ
Adjustment trimmer for the Right channel input.
[15] RIGHT
XLR connector, balanced Right channel input.
[16] IMPEDANCE
Dip-switch to set the balanced input impedance, 600Ω or
10kΩ.
[17] FUSE R
Mains power supply fuse.
[18] SERVICE
Reserved for future implementations.
[19] FUSE T
Mains power supply fuse.
[20] FUSE S
Mains power supply fuse.
[21] INPUT POWER
Not used.
[22] R.F. OUTPUT
RF output connector, type 7/8” EIA Flange, 50Ω.
[23] INTERLOCK OUT
Interlock output BNC connector: when the transmitter goes
into stand-by mode, the (normally floating) central conductor
is switched to ground.
[24] SERVICE
DB9 connector for interconnection with other devices and for
factory parameters programming.
[25] INTERLOCK IN
Interlock input BNC connector: the exciter is forced in
standby mode when the inner conductor is grounded.
[26] FWD EXT. AGC
Trimmer for the control of the delivered power in function of
the FWD fold input.
[27] RFL EXT. AGC
Trimmer for the control of the delivered power in function of
the RFL fold input.
[28] MODEM/LAN
Reserved for optional implementations.
[29] REMOTE
DB15 connector for telemetry of the machine.
[30] RS232
DB9 connector for direct serial communication or modem
(only with telemetry option).