State 1
As soon as operating conditions are restored, power output is re-enabled with the
same settings in use prior to the alarm condition.
Under 20kHz, no modulation occurs. After a preset time of about 5 minutes (not
editable), a NO AUDIO condition is indicated in the main screen, but power is not
inhibited.
State 2
To gain access to a submenu, select menu name (name is highlighted by cursor)
using button or and press the
ENTER
button.
To return to the
default menu
(menu 1), simply press
ESC
again.
5.3.1 Operation Menu (Fnc)
In this menu, you can toggle transmitter
power output
On/Off, set
deviation
display mode
and the threshold rate for
Forward
(
PgD
) or
Reflected
(
PgR
)
Power Good.
To edit an item, highlight the appropriate line using the and buttons and
then press and hold the
ENTER
button until the command is accepted. This way,
Pwr setting is toggled between On and Off and Mod setting is toggled between
“x1” and “x10”. To edit the Power Good rate, simply select item “PgD” or “PgR” and
edit its value using the UP and DOWN buttons; finally, press
ENTER
to confirm.