Pwr
Enables (ON) or disables (OFF) transmitter power output.
Mod
Modifies modulation display (toggles between “x1” and “x10”). In “x10”
mode, instantaneous deviation indication is multiplied by a factor of 10,
and the bar meter on the default menu will reflect 7.5 kHz instead of
75 kHz. This display mode is convenient when you wish to display low
deviation levels, such as those caused by pilot tone or subcarriers.
PgD
Modifies Power Good threshold for forward power. The Power Good
rate is a percent of equipment rated power (3500W for
TEX3500LCD
),
not of forward output power. This means that this threshold set at 50%
will give 1750 W, respectively, regardless of set power level. The Power
Good feature enables output power control and reporting. When output
power drops below set Power Good threshold, the equipment changes
the state of pin [7] of the DB15 “Remote” connector located on the rear
panel.
PgR
Modifies Power Good threshold for reflected power. The Power Good
rate is a percent of equipment rated power (350W for
TEX3500LCD
),
not of reflected output power. This means that this threshold set at 4%,
respectively, will give 14W regardless of set power level. The Power
Good feature enables output power control and alarm management.
NOTE: This alarm does not trip any contacts in the DB15 “Remote” connector and
is only available in systems equipped with telemetry.
5.3.2 Power Menu (Pwr)
This screen holds all readings related to equipment output power:
Menu 6
Fwd
Forward power reading.
Rfl
Reflected power reading.
Note that these are readings, rather than settings, and cannot be edited (note
the empty triangle). To change power setting, go to the
default menu
as outlined
earlier.