SDC2000
14 / 40
User Manual
Rev. 1.0 - 12/04/05
If the encoder is pushed when in this submenu, field [BACK] begins
to blink and you will be able to move the cursor from field to field by
turning the knob in the desired direction.
Push the encoder again when a field is selected to confirm that you
wish to edit the current selection.
[BACK]
Push the encoder when this item is blinking to cancel
selection mode and go back to scrolling through display
screens by turning the knob.
[Ri=10K] Push the encoder when this item is blinking to select
analogue input impedance; you may toggle selection
between 10 kOhm and 600Ohm.
[Anl-lv]
In this submenu, you may use the knob to set the right
and left analogue input levels.
Move back to exit the clock setting window; move forward
to access edit mode for available parameters.
Use the knob to move the cursor to the parameter you
wish to edit; when cursor is on the parameter, push the
encoder and edit as required.
Using the knob, you may cause the right channel, the left
channel or both to blink.
Push the encoder when the cursor is on one of these
items to enable edit mode; the label becomes steady
and the value begins to blink. The value displayed in
edit mode is the level required to achieve a 0 dBu
output level.
The allowed setting range is +/-12 dBu.
[Dgt-lv]
In this submenu, you may use the knob to set the right
and left digital input levels.
Move back to exit the menu; move forward to access
edit mode for available parameters.
Use the knob to move the cursor to the parameter you
wish to edit; when cursor is on the parameter, push the
encoder and edit as required.