Push the encoder when the cursor is on one of these
items to enable edit mode; the label becomes steady
and the value begins to blink. The value displayed in edit
mode is the level required to achieve a 0 dBu output level.
The allowed setting range is +/-12 dBu in 0.1 dB
increments.
[Output]
If the encoder is pushed when in this submenu, field [BACK]
begins to blink and you will be able to move the cursor from field to
field by turning the knob in the desired direction.
Push the encoder again when a field is selected to confirm that you
wish to edit the current selection.
[BACK]
Push the encoder when this item is blinking to cancel
selection mode and go back to scrolling through display
screens by turning the knob.
[Analog]
In this submenu, you may use the knob to set analogue
output levels.
•
[BACK] Push the encoder when this item is blinking
to cancel selection mode and go back to scrolling
through display screens by turning the knob.
•
Mpx - lvl: [+ 06,00] This field lets you set MPX output
level. The allowed setting range is +/-12 dBu in 0.1 dB
increments.
•
Mon - lv: [+ 00,00] This field lets you set MONITOR
output level. The allowed setting range is +/-12 dBu in
0.1 dB increments.
The MPX output signal is formed by CODER + pilot +
RDS + SCA.
The MONITOR output provides the 19kHz reference pilot
signal with adjustable 0 dBu level.