SDC2000
18 / 40
User Manual
Rev. 1.0 - 12/04/05
Push the encoder when the cursor is on one of these
items to enable edit mode; the label becomes steady
and the value begins to blink. The value displayed in edit
mode is the level required to achieve a 0 dBu output level.
The allowed setting range is 0 to -24 dBfs in 0.1 dB
increments.
[Dg-set]
In this submenu, use the knob to set digital input
parameters.
Move back to exit the menu; move forward to access
edit mode for available parameters.
Use the knob to move the cursor to the parameter you
wish to edit; when cursor is on the parameter, push the
encoder and edit as required.
•
Track: [01.01-01:49] This field shows the information
contained in audio. When no valid information is
available, fields are filled with "#" characters. When valid
information is available, the field shows information on:
[track.sector- minutes:seconds].
•
Sts:[00] This is the status field; if other than 0, audio is
treated as invalid. When this field is other than 0 and
"AUTO" mode is enabled, the system will switch to
analogue.
•
[Vbit] This field enables or disables detection of a
validity error condition of the received frame. When
enabled "[Vbit]", in the event of an error the system
switches to analogue (if allowed). When disabled "[--]",
in the event of an error the system will not switch to
analogue (if allowed). When an alarm is triggered by
an invalid or compromised frame, it is reported in field
Sts (Sts:[08]).
•
[Conf] This field enables or disables detection of a
coherent reception error. When enabled “[Conf]”, in the
event of an error the system switches to analogue (if
allowed). When disabled “[—]”, in the event of an error
the system will not switch to analogue (if allowed). When
an alarm is triggered by a frame not conforming to
receiver specifications, it is reported in field Sts
(Sts:[04]).