ZRB46
Z46FK Fan Kit Installation
Fan Kit should be installed
before
facing material is applied or surround is installed. To
remove
fan for service, the burner
pan must be removed and work done through the opening (See
Burner System Removal
section).
1
. Remove Lower Face Panel
(See
Removable Lower Face Panel
Section in manual).
2
. Lift UHS Box out of Unit
3
. Insert fan and place at right rear
corner of unit. See Component
Locations Section in manual.
4.
Mount fan on tabs
⚠
WARNING
Electrical Grounding Instructions
This appliance is equipped with a three prong (grounding) plug for
your protection against shock hazard and should be plugged
directly into a properly grounded three-prong receptacle. Do not
cut or remove the grounding prong from this.
Before Servicing
1. Ensure all power supply is shut off.
2. Label all wires prior to disconnecting when servicing control.
Wiring errors can cause improper and dangerous operation.
3. For fan servicing: Vacuum and clean lint/dirt build-up on the
fan blades and motor.
4. When resealing the Burner Pan, use
Millpac
.
NOTE: Do not allow cords or wires to come into contact
with the firebox or the underside of the burner pan.
TAB
THERMODISC
VALVE
Fan Speed
Control
MUST be
located
outside of
fireplace
Thermodisc
Located
under Burner
pan
TAB
5.
Connect fan as per
wiring diagram above.
Replace UHS Box and
Lower Face Panel.
Thermodisc
is located on Slider to the right of valve.
To replace pull handle out. Replace Thermodisc. Slide back in.
THERMODISC
HANDLE
SLIDER
Fan Speed Control
MUST be located
outside of fireplace
34