QWICK KURB
®
, INC.
Long Term Installation Manual
WATER CHANNELS AND SPACING MARKERS/BOLLARDS
USING WATER CHANNELS
Because water is able to run under the L60 SEPARATOR units, water channels are normally
not needed. However, if additional water flow is desired because of unusual climate,
drainage or roadway slope conditions, channels may be created by facing the downslopes of
opposing L61 Male and L62 Female End units toward one another, and separating them by
several inches.
If additional water channels are needed after the installation is complete, remove and
replace an existing L60 SEPARATOR with an L61 Male and L62 Female End unit. This will
create a water channel of approximately three inches.
NOTE: The longer the length of connected L60 SEPARATOR, the stronger the system, so use the
fewest possible water channels.
SPACING THE REBOUNDABLE MARKERS/BOLLARDS
Markers/bollards are typically placed on the one-meter L60 SEPARATOR units at intervals
ranging from one to seven units, that is, spaced from about 3 to 25 feet. Close spacing
should be used for areas where drivers may be inclined to attempt crossing the L60
SEPARATOR, such as into popular commercial establishments.
Each L60 SEPARATOR unit can accept a maximum of one marker or bollard. This equates
to a 3.35’ on center spacing of the markers. But often they are spaced further apart. Spacing
of markers/bollards every other SEPARATOR unit equates to a 6.7’ on center spacing, and
so on.
Phone: 800-324-8734
Fax: 813-645-4856
www.qwickkurb.com
1/21/2016
13