Instruction Book
9828 0934 73
99
Fuses
Dryer
Supply voltage
Maximum fuses, mandatory type:
Class JJS-15 Bussmann type UL class T
600V
QPVS-650 (
ES 310 VSD
)
460 V
3 x 15 A
QPVS-850 (
ES 410 VSD
)
460 V
3 x 15 A
QPVS-1050 (
ES 510 VSD
)
460 V
3 x 15 A
Fuses
Dryer
Supply voltage
Maximum fuses, mandatory type:
Class gG ABB type OFAF000H16 000 Size
500V
QPVS-650 (
ES 310 VSD
)
400 V
3 x 16 A
QPVS-850 (
ES 410 VSD
)
400 V
3 x 16 A
QPVS-1050 (
ES 510 VSD
)
400 V
3 x 16 A
Electrical cable size
Dryer
Supply voltage
Supply cable section, recommended
QED-650 (
ES 310
)
400 V
3 x 4 mm
2
+ 4 mm
2
QPVS-650 (
ES 310 VSD
)
400 V
3 x 4 mm
2
+ 4 mm
2
QED-850 (
ES 410
)
400 V
3 x 4 mm
2
+ 4 mm
2
QPVS-850 (
ES 410 VSD
)
400 V
3 x 4 mm
2
+ 4 mm
2
QED-1050 (
ES 510
)
400 V
3 x 4 mm
2
+ 4 mm
2
QPVS-1050 (
ES 510 VSD
)
400 V
3 x 4 mm
2
+ 4 mm
2
QED-650 (ES 310 )
460 V
3 X AWG 12 + AWG 12
QPVS-650 (ES 310 VSD)
460 V
3 X AWG 12 + AWG 12
QED-850 (ES 410)
460 V
3 X AWG 12 + AWG 12
QPVS-850 (ES 410 VSD)
460 V
3 X AWG 12 + AWG 12
QED-1050 (ES 510)
460 V
3 X AWG 10 + AWG 10
QPVS-1050 (ES 510 VSD)
460 V
3 X AWG 12 + AWG 12
Содержание QED 1050
Страница 2: ......
Страница 4: ...Instruction Book 4 9828 0934 73...
Страница 89: ...Instruction Book 9828 0934 73 89 Dimension drawing of air cooled QED 1050 ES 510 imperial units...
Страница 90: ...Instruction Book 90 9828 0934 73 Dimension drawing of air cooled QED 1050 ES 510 metric units...
Страница 94: ...Instruction Book 94 9828 0934 73 4 2 Installation proposal Example Installation proposal metric unit...
Страница 134: ...02 2021 No 9828 0934 73 Ed 00...