QuercusVL Programming Manual
●
Type: 1
●
Message Data:
●
Code (Cod): type of received notification
○
0: the status of the unit changed.
○
1: the startup of the unit has been correct.
○
2: the startup of the unit has been incorrect.
○
3: the shutdown of the unit has been correct.
○
4: the shutdown of the unit has been incorrect.
4.6.3. SummaryInformation
Indicates that a summary has been received.
●
Type: 2
●
Message Data:
●
Begin: timestamp when summary data collection started; in seconds elapsed
since 00:00 hours on the first of January of 1970.
●
End: timestamp when summary data collection finished; in seconds elapsed
since 00:00 hours on the first of January of 1970.
●
DetectorId: identifier of the detector that generated the summary.
●
DetectorType (Type): type of detector that generated the summary:
○
1: speed detector.
○
2: queue detector.
○
3: presence detector.
○
4: red light detector.
Quercus Technologies
140
1
Cod
4
Begin
4
End
4
DetectorId
4
Volume
4
AvgSpeed
4
AvgLength
4
AvgHeadway
SpdDst
28
SpdUL
28
LenDst
28
LenUL
28
OccDst
28
28
OccUL
1
Type
4
RedLightTime