Smart Module Series
SA800U-WF Hardware Design
SA800U-WF_Hardware_Design 74 / 106
Table 25: DSI Data Rate and PCB Maximum Trace Length (D-PHY)
1.
The flex cable length used in this table is an example with specified insertion loss
.
2.
The flex cable insertion loss can be measured using a vector signal analyzer or obtained from the flex
cable datasheet. Cable insertion loss on the design should be no worse than what is listed above.
3.
The maximum PCB trace length listed above includes the length routed inside the module.
Table 26: MIPI Trace Length Inside the Module
Data Rate
Flex Cable Length
(inch)
Cable Insertion Loss
(dB)
Maximum PCB Trace
Length (mm)
500 Mbps/lane
3
-0.8
< 280
6
-1.4
< 210
750 Mbps/lane
3
-1
< 210
6
-1.5
< 150
1.0 Gbps/lane
3
-1.1
< 200
6
-1.7
< 100
1.5 Gbps/lane
3
-1.2
< 135
6
-2.2
< 40
2.1 Gbps/lane
3
-1.6
< 110
6
-2.8
0
Pin No.
Pin Name
Length (mm)
Length Difference (P - N)
J2-26
DSI0_CLK_N
13.12
0.15
J2-28
DSI0_CLK_P
13.27
J2-38
DSI0_LN0_N
13.41
-0.52
J2-40
DSI0_LN0_P
12.89
J2-32
DSI0_LN1_N
13.21
-0.43
J2-34
DSI0_LN1_P
12.78
NOTES