Timer

Set time on QK-021/022

SThhmmss#

Where hhmmss is the

current time

For example, by sending

’ST153000#

’, the

operator set G031 time as 15:30:00. G031 will

return the message ‘

Time setup successful’

to

accept this setting. If the operator sends the

wrong time format, G031 will return the

message ’Time setup failed’.

Check the local time on

QK-021/022

DQSJ

By sending ‘

DQSJ’

, the operator will receive the

local time. The message received would be ‘

Time

at terminal is 12:30:32’.

Set Switching Relays ON

time

ONnhhmmss#

n=1, Relay 1

n=2, Relay 2
hhmmss is the Switch ON

time.

For example, by sending ‘

ON2163000#

’, the

operator set Switch Relay 2 ON at 16:30:00.

Message as ‘

Port 2 will switch ON’

will be

returned to operator if the setting successful.

Set Switching Relays

OFF time

OFnhhmmss#

n=1, Relay 1

n=2, Relay 2
hhmmss is the Switch

OFF time.

For example, by sending

‘OF2194500’

, the

operator set Switch Relay 2 OFF at 19:45:00.

Message as

‘Port 2 will switch OFF’

will be reply

to operator if the setting successful.

Check the current setting

of the timer

RELAYnTIMER

n=1, Relay 1

n=2, Relay 2

For example, by sending ‘

RELAY2TIMER’

, the

timer setting on reply 2 will be reply to operator.

The replied message will be similar as

’Port 2 will

switch ON at 12:30;00 and switch OFF at

13:30:00’

Switch off the Timer

setting

GDSn

n=1, Relay 1

n=2, Relay 2

Message ‘

Timer on Relay n has switched OFF’

will be returned to the operator if the setting is

successful; where n is ‘

1

’ or ’

2

’.

Note: The local time will not be affected by

switching off the timer.

Monitoring/alarm input

Releases relay status

which is triggered by the

external signals.

EXTRT

After it has been triggered by the alarm input, the

related relay will be locked in the normal state. By

sending

‘EXTRT’

, the relays will be unlocked and

available for responding to SMS commands

again.

Disable the function of

been triggered by

external signals.

EXTGBn

n=1, Relay 1

n=2, Relay 2
n=3, only available for

PIRwireless PIR detector

(QK-G022P variant)

By sending

‘EXTGBn’

, the external alarm input n

will be disabled. Message ‘

Alarm input n has

been disabled

.’ will be returned to the operator if

the setting is successful, where n is ‘1’ ‘2’or’3’.

By sending ‘

EXTRT

’ all external alarm inputs will

be active.

This disable status doesn’t affect by re-powering
up the module, only

‘EXTRT’

can.

G031 has two digital input ports which can be used to monitor external signals. These two external input

ports can accept 0.0 V to 24.0 V voltage levels. Should the input voltage level be below 1.0 V, the main

mobile terminal will receive the warning message ‘Port n has been triggered’, where n is the relay number.

The relay n will switch to the normal state (NC will be the closed state and NO will be the open state).

Sending ‘EXTRT’ will release the relays and make them available for responding to SMS commands.

Содержание QK-G031

Страница 1: ...ntrol of 3 Relay outputs activated by temperature sensors and temperature ranges Scheduled control of 3 Relay outputs by SMS message In built clock for programming scheduled switch state Status reques...

Страница 2: ...umber 9 8 Alarm function connections 10 9 Relays 11 9 1 Relay wiring 11 9 2 Daily timer setting 11 9 3 Relay working mode relay 1 and 2 12 9 4 Latching mode settings 13 10 Temperature monitoring contr...

Страница 3: ...he circuit and alarm inputs that send a low voltage signal 5 Connect temperature sensors by inserting the connector block into the slots at the back of the G031 Good practice is to label each sensor a...

Страница 4: ...ction to the equipment that is to be controlled o Relay 1 Manual SMS control Automated control Daily timer o Relay 2 Manual SMS control Automated control Daily timer o Relay 3 Manual SMS control Three...

Страница 5: ...Quark elec Manual https www quark elec com 5 of 28 2018 V3 3 Enclosure The enclosure is made of IP56 Insulation Class 2 plastic External dimension 145 x 90 x 41 mm...

Страница 6: ...3 seconds 4 2 Battery connections The G031 supports backup battery inputs The battery can be an auxiliary power supply for operation during mains power failure A 12 0V rechargeable Li ion or Lead acid...

Страница 7: ...lower every 3 seconds Red System led Red led will flash at 1 second intervals once the system has finished initialization It will not flash while it is processing a command Remember the device process...

Страница 8: ...ically Top Up when the credit falls below a certain limit Some PAYG SIM cards will be de activated by the network if they are not used to make an outgoing voice call or send an SMS text message within...

Страница 9: ...sends the SMS message for you App sent messages will be charged at your normal text rate 7 Resetting The G031 has two types of reset You can Factory reset the module itself Reset the main SIM control...

Страница 10: ...number External alarm 1 INT1 Relay 1 External alarm 2 INT2 Relay 2 There are two typical ways the external alarm inputs can communicate with G031 External alarm devices can be used as 1 Switch 2 Alar...

Страница 11: ...g setup Normal closed position if common and normal closed are wired then relay 1 will be active while the G031 is powered up This can be useful for fail safe systems where the power going off in the...

Страница 12: ...nds to alert the user To change between self lock and latching control the jumpers must be moved from one connection to another Carefully lift the jumper unit up vertically from the unit Be very caref...

Страница 13: ...ovides a one off action timer command SMS commands in ONOFFRnxxx format support action times from 001 second to 999 seconds n indicates the relay number 1 2 3 xxx means the delay times from 001 to 999...

Страница 14: ...imarily for a heating setup but can also be used for cooling The wiring is different depending on whether you are using the relay for a heating or cooling function The ON temperature must be at least...

Страница 15: ...e Normal Closed configuration as seen in the table below It is important to understand that relays wired in normal closed position will operate in the opposite way than expected In this setup off will...

Страница 16: ...ws for up to two G031 devices to be controlled from a single mobile operator You will still be charged at your normal text rate for the messages created by this app To download the app Android The lat...

Страница 17: ...s Device 1 in the app If you have 2 QK G031 devices then you can enter the second SIM card number where it says Device 2 The app will save these numbers so you don t have to keep entering them Input t...

Страница 18: ...dditional SIM cards These additional SIM numbers are authorized to control the G031 Check registered SIM numbers this will give the user a list of the telephone numbers that are authorized t control t...

Страница 19: ...a the app Relay working mode This will inform the user which relays are in self lock or latching mode This is for relays 1 and 2 Relay working status This tells the users which relays are on off if wi...

Страница 20: ...er to turn the relay into the normal open position You must wait for the command to be received before issuing another command to the controller The off button operates the relay to the normal closed...

Страница 21: ...wing a command to be received by the G031 This command will usually be followed by either Disable alarm input or relay off command Disable alarm input this will disable the alarm input of the chosen r...

Страница 22: ...ure alert this command enables temperature alerts being sent to the controllers Disable alarm alert this command stops input alarm alerts being sent to the controllers This is very useful because for...

Страница 23: ...will allow any mobile terminal to replace the main mobile number by sending 88888888 within 600 seconds Register additional SIM cards BDn mobile number F n 1 1st additional mobile n 2 2nd additional...

Страница 24: ...k mode For example INCH1SELF2 means relay 1 works in Latching control mode and relay 2 works in Self lock mode Check relay working status WHOACTIVE G031 will reply with the relay working status inform...

Страница 25: ...h off the Timer setting GDSn n 1 Relay 1 n 2 Relay 2 Message Timer on Relay n has switched OFF will be returned to the operator if the setting is successful where n is 1 or 2 Note The local time will...

Страница 26: ...ve been set as Ch1 On Ch2 Off Ch3 On will be returned to the operator if the setting is successful Set the temperature limit for relays TEMPnxxxxtoxxxx n 1 Relay 1 n 2 Relay 2 n 3 Relay 3 Xxxx is a 4...

Страница 27: ...ly switch back to using mains power The following message will be sent to the operator Mains power has been restored G031 is powered by mains again now 13 Specification Item Specification Frequency ba...

Страница 28: ...t the statutory rights of the consumer Disclaimer It is the user s responsibility to use this product prudently Neither Quark nor their distributors or dealers accept responsibility or liability eithe...

Отзывы: