Quark-elec Manual
https://www.quark-elec.com
9 of 28
2018
V3
6.3.Registering additional SIM controllers
You can add up to three additional control mobile phones. When adding additional numbers to the unit
you must enter them in the correct format used by the Network service provider of the SIM that you have
entered into the G022. For example, if the UK number 07123456789 needs adding; then we have three
formats to try (Using the UK country code '44').
1.
+447123456789
2.
00447123456789
3.
07123456789
The most commonly used, is format 1, this will work with most providers. To store your number, text
‘
BD1+447123456789F’
to the device. If you are able to send commands from the new number but do
not receive messages back, try one of the other formats.
You can now control the device by either:
Manually entering the codes by SMS text message
Using the phones Android APP interface. Using the APP, simply select the action you want and the
APP formulates and sends the SMS message for you.
App sent messages will be charged at your normal text rate.
7. Resetting
The G031 has two types of reset. You can:
Factory reset the module itself.
Reset the main SIM controller SIM number (main mobile number in control of module), whilst
keeping other settings.
7.1. Factory reset G031 memory
1. Hold the reset button for 10 seconds – the red LED should stay constantly on.
2. You now have 600 seconds to send the message ‘
88888888
’ to the SIM card in the G031
3. This will register you as the main SIM controller.
You can also reset the Main controller SIM remotely, For example when the main SIM controller number
has changed or you need to reset permissions for the main controller. This code allows you to remotely
remove and reset all mobile phone numbers stored in the device.
7.2. Reset main controller SIM number
1. Send ‘
XGZHM
’ command via text to the G031 SIM.
2. send ‘
88888888
’ within 600 seconds to the G031
3. The module will reply with ‘
Your phone has been registered’
.
If the G031 replies with the message ‘
registered disabled’
or
‘Registered not allowed. Please Factory
reset G031 module first’
then repeat factory reset steps.