11.2.Register SIM cards

G031 allows one mobile phone to function as the main controller and up to 3 additional phones to function as

control terminals. The following interface allows the operator to register, delete and check the SIM card

numbers:

Register myself as main SIM card

: When starting the G031 for

the first time you will need to add the main controller SIM number

to the device. Do this by entering the mobile number you would

like to be the main controller or ‘

click register myself as main

SIM card’

. There must always be a main controller for each

device.

You will have ten minutes to register the main controller SIM

once you power up the G031. If not repower the device and

retry.

Register 1st, 2nd, 3rd additional SIM card:

click this button to

register additional SIM cards. These additional SIM numbers are

authorized to control the G031

Check registered SIM numbers:

this will give the user a list of

the telephone numbers that are authorized t control the G031

Replace the main SIM numbers:

this allows for the main

controller SIM to be reset. Once this message is received by the

G031, the user will have 10 minutes to register the main SIM.

11.3.Setting the clock on the QK controller

G031 can automatically execute actions at the time set by the operator. To do this, the real time clock on the

G031 controller must be set. This page allows the operator to check and set the time on G031 internal clock.

Set clock on QK controller:

To set the time on the G031 enter

the current time in the white box. The time format is 24hour (i.e.

11.55.00). When complete click submit to set this as the G031’s

time.

Check the clock on QK controller:

To request the time on the

G031, click request at the top of the page. This will send a

message saying the time relative to the G031’

s internal clock.

Содержание QK-G031

Страница 1: ...ntrol of 3 Relay outputs activated by temperature sensors and temperature ranges Scheduled control of 3 Relay outputs by SMS message In built clock for programming scheduled switch state Status reques...

Страница 2: ...umber 9 8 Alarm function connections 10 9 Relays 11 9 1 Relay wiring 11 9 2 Daily timer setting 11 9 3 Relay working mode relay 1 and 2 12 9 4 Latching mode settings 13 10 Temperature monitoring contr...

Страница 3: ...he circuit and alarm inputs that send a low voltage signal 5 Connect temperature sensors by inserting the connector block into the slots at the back of the G031 Good practice is to label each sensor a...

Страница 4: ...ction to the equipment that is to be controlled o Relay 1 Manual SMS control Automated control Daily timer o Relay 2 Manual SMS control Automated control Daily timer o Relay 3 Manual SMS control Three...

Страница 5: ...Quark elec Manual https www quark elec com 5 of 28 2018 V3 3 Enclosure The enclosure is made of IP56 Insulation Class 2 plastic External dimension 145 x 90 x 41 mm...

Страница 6: ...3 seconds 4 2 Battery connections The G031 supports backup battery inputs The battery can be an auxiliary power supply for operation during mains power failure A 12 0V rechargeable Li ion or Lead acid...

Страница 7: ...lower every 3 seconds Red System led Red led will flash at 1 second intervals once the system has finished initialization It will not flash while it is processing a command Remember the device process...

Страница 8: ...ically Top Up when the credit falls below a certain limit Some PAYG SIM cards will be de activated by the network if they are not used to make an outgoing voice call or send an SMS text message within...

Страница 9: ...sends the SMS message for you App sent messages will be charged at your normal text rate 7 Resetting The G031 has two types of reset You can Factory reset the module itself Reset the main SIM control...

Страница 10: ...number External alarm 1 INT1 Relay 1 External alarm 2 INT2 Relay 2 There are two typical ways the external alarm inputs can communicate with G031 External alarm devices can be used as 1 Switch 2 Alar...

Страница 11: ...g setup Normal closed position if common and normal closed are wired then relay 1 will be active while the G031 is powered up This can be useful for fail safe systems where the power going off in the...

Страница 12: ...nds to alert the user To change between self lock and latching control the jumpers must be moved from one connection to another Carefully lift the jumper unit up vertically from the unit Be very caref...

Страница 13: ...ovides a one off action timer command SMS commands in ONOFFRnxxx format support action times from 001 second to 999 seconds n indicates the relay number 1 2 3 xxx means the delay times from 001 to 999...

Страница 14: ...imarily for a heating setup but can also be used for cooling The wiring is different depending on whether you are using the relay for a heating or cooling function The ON temperature must be at least...

Страница 15: ...e Normal Closed configuration as seen in the table below It is important to understand that relays wired in normal closed position will operate in the opposite way than expected In this setup off will...

Страница 16: ...ws for up to two G031 devices to be controlled from a single mobile operator You will still be charged at your normal text rate for the messages created by this app To download the app Android The lat...

Страница 17: ...s Device 1 in the app If you have 2 QK G031 devices then you can enter the second SIM card number where it says Device 2 The app will save these numbers so you don t have to keep entering them Input t...

Страница 18: ...dditional SIM cards These additional SIM numbers are authorized to control the G031 Check registered SIM numbers this will give the user a list of the telephone numbers that are authorized t control t...

Страница 19: ...a the app Relay working mode This will inform the user which relays are in self lock or latching mode This is for relays 1 and 2 Relay working status This tells the users which relays are on off if wi...

Страница 20: ...er to turn the relay into the normal open position You must wait for the command to be received before issuing another command to the controller The off button operates the relay to the normal closed...

Страница 21: ...wing a command to be received by the G031 This command will usually be followed by either Disable alarm input or relay off command Disable alarm input this will disable the alarm input of the chosen r...

Страница 22: ...ure alert this command enables temperature alerts being sent to the controllers Disable alarm alert this command stops input alarm alerts being sent to the controllers This is very useful because for...

Страница 23: ...will allow any mobile terminal to replace the main mobile number by sending 88888888 within 600 seconds Register additional SIM cards BDn mobile number F n 1 1st additional mobile n 2 2nd additional...

Страница 24: ...k mode For example INCH1SELF2 means relay 1 works in Latching control mode and relay 2 works in Self lock mode Check relay working status WHOACTIVE G031 will reply with the relay working status inform...

Страница 25: ...h off the Timer setting GDSn n 1 Relay 1 n 2 Relay 2 Message Timer on Relay n has switched OFF will be returned to the operator if the setting is successful where n is 1 or 2 Note The local time will...

Страница 26: ...ve been set as Ch1 On Ch2 Off Ch3 On will be returned to the operator if the setting is successful Set the temperature limit for relays TEMPnxxxxtoxxxx n 1 Relay 1 n 2 Relay 2 n 3 Relay 3 Xxxx is a 4...

Страница 27: ...ly switch back to using mains power The following message will be sent to the operator Mains power has been restored G031 is powered by mains again now 13 Specification Item Specification Frequency ba...

Страница 28: ...t the statutory rights of the consumer Disclaimer It is the user s responsibility to use this product prudently Neither Quark nor their distributors or dealers accept responsibility or liability eithe...

Отзывы: