background image

Quark-elec Manual

https://www.quark-elec.com

3 of 28

2018

V3

1. Setup overview
You will need:

SIM card:

SIM must operate on the GSM (2G) network for this version.

Check with your SIM supplier.

Credit on the SIM (we recommend automatic top-ups)

The SIM is not PIN protected

The SIM is set to disable voicemail

Avoid SIM cards that deactivate automatically if the SIM is not used often.

If your G031 is likely to

be unused for long periods of time, you will have to send the G031 an update request periodically to keep

the SIM card active. The time limit is often three months.

2. Power supply cable:

long enough to reach your device in its final location.

3. Check there is mobile network reception for your SIM card

in the location that your device will be

installed (you can check the SIM card in a mobile phone).

4. Temperature sensors (included)

which come in 1, 2 and 6 metre lengths and can be shortened or

extended (we recommend a maximum of 8 metres).

5. Optional liquid cell 12.0V battery:

Can be plugged into G031 for backup power.

Installation

1. Download and install the APP

https://www.quark-elec.com/downloads/APPs/

2. Select G031 location:

location must be indoors and not exposed to water or high humidity.

3. Connect the relays outputs

(if required): check relay setup for whether you want relays in normal

open (NO) or normal closed (NC) position. See back page.

4. Connect alarm inputs

(if required) to the correct terminal: alarm inputs (INT) 1/2 will activate relay 1/2

respectively. The G031 is compatible with inputs that send signals as a switch (by closing the circuit) and

alarm inputs that send a low voltage signal.

5. Connect temperature sensors

by inserting the connector block into the slots at the back of the G031.

Good practice is to label each sensor and its corresponding relay. This will help later on.

6. Insert your SIM into the G031 device

(make a note of the SIM number first for reference).

7. Connect to power:

Check LEDs are working correctly.

Blue Network LED

: LED will flash blue at start up as it is connecting to a network. Once

connected, the LED will flash once every 2 to 3 seconds.

Red System LED

: will flash at 1 second intervals once the system has finished initialization. The LED

will not flash while the G031 is processing a command.

8. Hold down reset button for 10 seconds.
9. Register the main phone number that will control the device within 10 minutes of powering up

the G031

by texting ‘

88888888’

from your chosen phone to G031 SIM card. If registration is successful,

the module will reply with ‘

Your phone has been registered

’. If unsuccessful, the module will reply with

registered disabled’

. If registration is unsuccessful, Hold down reset button for 10 seconds and

reattempt registration within 10 minutes. The system LED will flash at one second intervals once the

registration is completed. You can add up to three additional control mobile phones (check the manual for

full list of text command codes).

You can send commands and receive updates by SMS text or the text generating android APP.

Remember; the device processes one command at a time. Each command will have a reply to

confirm the command has been received and executed. You must wait for a reply message before

sending another command.

(This is an overview only. Familiarize yourself with the manual before installation.)

Содержание QK-G031

Страница 1: ...ntrol of 3 Relay outputs activated by temperature sensors and temperature ranges Scheduled control of 3 Relay outputs by SMS message In built clock for programming scheduled switch state Status reques...

Страница 2: ...umber 9 8 Alarm function connections 10 9 Relays 11 9 1 Relay wiring 11 9 2 Daily timer setting 11 9 3 Relay working mode relay 1 and 2 12 9 4 Latching mode settings 13 10 Temperature monitoring contr...

Страница 3: ...he circuit and alarm inputs that send a low voltage signal 5 Connect temperature sensors by inserting the connector block into the slots at the back of the G031 Good practice is to label each sensor a...

Страница 4: ...ction to the equipment that is to be controlled o Relay 1 Manual SMS control Automated control Daily timer o Relay 2 Manual SMS control Automated control Daily timer o Relay 3 Manual SMS control Three...

Страница 5: ...Quark elec Manual https www quark elec com 5 of 28 2018 V3 3 Enclosure The enclosure is made of IP56 Insulation Class 2 plastic External dimension 145 x 90 x 41 mm...

Страница 6: ...3 seconds 4 2 Battery connections The G031 supports backup battery inputs The battery can be an auxiliary power supply for operation during mains power failure A 12 0V rechargeable Li ion or Lead acid...

Страница 7: ...lower every 3 seconds Red System led Red led will flash at 1 second intervals once the system has finished initialization It will not flash while it is processing a command Remember the device process...

Страница 8: ...ically Top Up when the credit falls below a certain limit Some PAYG SIM cards will be de activated by the network if they are not used to make an outgoing voice call or send an SMS text message within...

Страница 9: ...sends the SMS message for you App sent messages will be charged at your normal text rate 7 Resetting The G031 has two types of reset You can Factory reset the module itself Reset the main SIM control...

Страница 10: ...number External alarm 1 INT1 Relay 1 External alarm 2 INT2 Relay 2 There are two typical ways the external alarm inputs can communicate with G031 External alarm devices can be used as 1 Switch 2 Alar...

Страница 11: ...g setup Normal closed position if common and normal closed are wired then relay 1 will be active while the G031 is powered up This can be useful for fail safe systems where the power going off in the...

Страница 12: ...nds to alert the user To change between self lock and latching control the jumpers must be moved from one connection to another Carefully lift the jumper unit up vertically from the unit Be very caref...

Страница 13: ...ovides a one off action timer command SMS commands in ONOFFRnxxx format support action times from 001 second to 999 seconds n indicates the relay number 1 2 3 xxx means the delay times from 001 to 999...

Страница 14: ...imarily for a heating setup but can also be used for cooling The wiring is different depending on whether you are using the relay for a heating or cooling function The ON temperature must be at least...

Страница 15: ...e Normal Closed configuration as seen in the table below It is important to understand that relays wired in normal closed position will operate in the opposite way than expected In this setup off will...

Страница 16: ...ws for up to two G031 devices to be controlled from a single mobile operator You will still be charged at your normal text rate for the messages created by this app To download the app Android The lat...

Страница 17: ...s Device 1 in the app If you have 2 QK G031 devices then you can enter the second SIM card number where it says Device 2 The app will save these numbers so you don t have to keep entering them Input t...

Страница 18: ...dditional SIM cards These additional SIM numbers are authorized to control the G031 Check registered SIM numbers this will give the user a list of the telephone numbers that are authorized t control t...

Страница 19: ...a the app Relay working mode This will inform the user which relays are in self lock or latching mode This is for relays 1 and 2 Relay working status This tells the users which relays are on off if wi...

Страница 20: ...er to turn the relay into the normal open position You must wait for the command to be received before issuing another command to the controller The off button operates the relay to the normal closed...

Страница 21: ...wing a command to be received by the G031 This command will usually be followed by either Disable alarm input or relay off command Disable alarm input this will disable the alarm input of the chosen r...

Страница 22: ...ure alert this command enables temperature alerts being sent to the controllers Disable alarm alert this command stops input alarm alerts being sent to the controllers This is very useful because for...

Страница 23: ...will allow any mobile terminal to replace the main mobile number by sending 88888888 within 600 seconds Register additional SIM cards BDn mobile number F n 1 1st additional mobile n 2 2nd additional...

Страница 24: ...k mode For example INCH1SELF2 means relay 1 works in Latching control mode and relay 2 works in Self lock mode Check relay working status WHOACTIVE G031 will reply with the relay working status inform...

Страница 25: ...h off the Timer setting GDSn n 1 Relay 1 n 2 Relay 2 Message Timer on Relay n has switched OFF will be returned to the operator if the setting is successful where n is 1 or 2 Note The local time will...

Страница 26: ...ve been set as Ch1 On Ch2 Off Ch3 On will be returned to the operator if the setting is successful Set the temperature limit for relays TEMPnxxxxtoxxxx n 1 Relay 1 n 2 Relay 2 n 3 Relay 3 Xxxx is a 4...

Страница 27: ...ly switch back to using mains power The following message will be sent to the operator Mains power has been restored G031 is powered by mains again now 13 Specification Item Specification Frequency ba...

Страница 28: ...t the statutory rights of the consumer Disclaimer It is the user s responsibility to use this product prudently Neither Quark nor their distributors or dealers accept responsibility or liability eithe...

Отзывы: