Chapter 3: FRU Removal and Replacement Procedures
Replacing an Array Module Controller
Quantum DXi6900 G2 Field Service Manual
162
Replacing an Array Module Controller
This section describes how to remove and replace a controller in a DXi6900 G2 Array module (RBOD).
Caution:
Use appropriate ESD precautions, including the use of a grounding strap, when performing
this procedure.
Removing and replacing an Array module controller includes the following steps:
l
Identifying a Failed Array Module Controller below
l
Removing a Failed Array Module Controller on the next page
l
Installing a Replacement Array Module Controller on page 165
Identifying a Failed Array Module Controller
The DXi6900 G2 contains one or two Array modules (RBODs). Each Array module contains two controllers
(A and B).
To identify the failed Array module controller:
1. Access the remote management console (see
).
2. Navigate to the
Status > Hardware > Details > Storage Arrays
page.
3. Note the status of each controller (A and B) in each Array module (see
).
Note: Qarray1
corresponds to RBOD 1, and
Qarray2
corresponds to RBOD 2.
Figure 107:
Checking Array Module Controller Status
4. Locate the failed controller on the back of the Array module by viewing the
Service Action LEDs
(see
).