Chapter 3: FRU Removal and Replacement Procedures
Replacing Array or Expansion Module Hard Drives
Quantum DXi6900 G2 Field Service Manual
155
Figure 99:
Enter Array Password
8. Enter the array password (Qa@Ar39!).
9. Click
OK
. The selected drive goes into a failed status (see
).
Figure 100:
Santricity Drive with a Failed Status
10. Once the drive fails, the
Service Action Allowed
).
11. Remove and replace the failed drive (see
Removing and Installing an Array or Expansion Hard Drive on
).
Removing a Drive from an Array or Expansion Module
To remove the failed hard drive from a DXi6900 G2 Array module (RBOD) or Expansion module (EBOD):
WARNING:
DO NOT replace a drive until determining its status. A drive with an impending failure or in
optimal status needs to be put into a failed state before removal. Failure to do this may cause issues
with the DXi6900 G2 system (see
Failing a Non-Critical Fault (NCF) or Optimal Hard Drive on
).