UANTA COMPUTER INC.
Layer 2/3/4 Managed Switch
_____________________________________________________________________________
LB9
User’s Guide 450/1523
6.10.2.8
sntp clock timezone
This command sets
the time zone for the switch’s internal clock.
Syntax
sntp clock timezone <name> <0-12> <0-59> {before-utc | after-utc}
<name> -
Name of the time zone, usually an acronym. (Range: 1-15 characters)
<0-12> -
Number of hours before/after UTC. (Range: 0-12 hours)
<0-59> -
Number of minutes before/after UTC. (Range: 0-59 minutes)
before-utc -
Sets the local time zone before (east) of UTC.
after-utc -
Sets the local time zone after (west) of UTC.
Default Setting
Taipei 08:00 After UTC
Command Mode
Global Config
6.10.2.9
sntp multicast client poll-internal
This command will set the poll interval for SNTP multicast clients in seconds.
Syntax
sntp multicast client poll-interval <poll-interval>
no sntp multicast client poll-interval
<poll-interval> -
Polling interval. It’s 2^(value) seconds where the range of value is 6 to 10.
no
–
This command will reset the poll interval for SNTP multicast client to its default value.
Default Setting
The default value is 6.
Command Mode
Global Config