511010 Rev. 07-01-19
Field–Replaceable Units (FRUs)
7-31
7.15.2
Replacing an Air Filter in a RLS-8350 library
Figure 7-27 Air Filter with a Storage Matrix Open (RLS-8350 shown)
1.
Slide the storage matrix forward until the air filter can be accessed.
2.
Grasp the air filter and pull it free from the lips securing it to the front of the
storage matrix.
3.
Replace the air filter with a new one (Qualstar P/N 510787-01-3). If an old air
filter is not yet dirty enough to be replaced and is being reinstalled, make sure
that the side that was facing the inside of the library is placed in the same direc-
tion as it was when it was removed. Reversing the direction of an old air filter
may cause dirt to be transferred into the library.
4.
Insert the air filter into the opening in the front of the storage matrix making
sure that it is centered.
5.
Flatten the air filter and tuck it under the lips to secure it.
6.
Slide the storage matrix closed and lock it.
7.
Repeat these steps for the second storage matrix if installed on the library.
Front of
Storage Matrix
Air Filter
Tuck the Air
Filter under
these lips.