7-16
Field–Replaceable Units (FRUs)
511010 Rev. 07-01-19
7.11.2
User Interface Panel Assembly Replacement
This procedure assumes that the User Interface Panel Assembly was removed in Sec-
tion 7.11.1.
1.
Align the guide pin at the bottom of the User Interface Panel Assembly with the
corresponding hole in the libraries frame and position it against the front of the
RLS.
2.
Use a No. 2 Phillips screwdriver to replace the two screws along the top of the
User Interface Panel Assembly. Then replace the screw on the bottom right side.
3.
Carefully reconnect the User Interface Panel Assemblies cable.
4.
Place the sheet metal cable guard on the RLS, making sure the tab is in the slot.
Secure the guard, using a No. 2 Phillips screwdriver and the long screw that was
removed earlier.
5.
If a storage matrix assembly blank was installed on the right side, replace as
shown in Section 7.6.2.
7.12
Drive Filler Assembly
P/N 510757-01-6
A Drive Filler Assembly must be installed in any tape drive opening on an RLS that
is not occupied by a tape drive. Please contact Qualstar Technical Support if addition-
al Drive Filler Assemblies are required.
Tools Required:
•
No. 2 Phillips Screwdriver (optional)
Figure 7-13 Drive Filler Assembly shown on rear of RLS
Screws
Drive Filler Assembly