7-26
Field–Replaceable Units (FRUs)
511010 Rev. 07-01-19
8.
Either re-using the screws and washers from the old rack rail assembly or those
that were supplied with the new one, attach the assembly to the rack using all
four mounting bracket holes on each slide assembly. Tighten the hardware se-
curely with a Number 2 Phillips screwdriver making sure that the washers are
in place as shown in Figure 7-21. Note that the washers have a specially de-
signed shoulder and can only be acquired from Qualstar. If new washers are re-
quired please contact technical support and request P/N 510703-01-0.
CAUTION
Do not attempt to replace the washers with any other washer that has not
been provided by Qualstar.
Figure 7-21 Screws and Washers securing a Rack Rail Assembly to the Rack Posts
9.
Using a 11/32” wrench, tighten all of the nuts that were loosened in step 3 when
the brackets were moved on the rack rail assembly.
10.
Repeat Steps 7 through 10 to attach the remaining rack rail assembly to the
rack.
11.
The library will be secured to the front rack posts using one screw on each side.
Two cage nuts need to be installed in the rack posts that correspond with the
mounting holes in the library. If the new rack rail assemblies have been placed
in the exact same location on the rails as the old assemblies the cage nuts should
still be in the correct locations.
Rear view of Qualstar wash-
er (P/N 510703-01-0) show-
ing the shoulder.