PAC25140 Users Guide Preview
No portion of this
document may be reproduced or reused in any form without Qorvo’s prior written consent
Rev. 1.0.0 28 February 2023 © 2023 Qorvo US, Inc.
46 of 77
SOC.HIBCTL
Register 8-6
. SOC.HIBCTL (Hibernate Control, SOC 0x05)
BIT
NAME
ACCESS
RESET
DESCRIPTION
7:5
WUTIMER
R/W
0x0
Wake Up Timer
Duration
0: Disabled
1: 125ms
2: 250ms
3: 500ms
4: 1s
5: 2s
6: 4s
7: 8s
4:3
WAKESRC
R/W
0x0
Wake Up Source
0:PB
1: PACK+
2: WUTIMER
3: RFU
2
PACKWAKEVREF
R/W
0x0
PACK+ Wake Up
Voltage Reference
Threshold
0: 5V
1: 20V
1
PACKWAKEEN
R/W
0x0
PACK+ Wake Up
Enable
0: Disabled
1: Enabled
0
PBWAKEEN
R/W
0x0
Push Button Wake Up
Enable
0: Disabled
1: Enabled
Note: If all wake-up enables are set to Disabled when HIBENTER.HIB is written, then PBWAKEN and
PACKWAKEN will be set to 1 as a fail safe to allow the device to be brought out of hibernate.