24
Installation & Operation Manual
Copyright © Puretec Pty Ltd 2020
Now programming is completed (if required) you are ready to start the system.
1. Fill the brine tank with ‘water softener’ salt to approximately half full (salt
not included).
This will require approximately 75 kg (this is only required initially).
2. Add approximately 15 litres of water to the salt in the brine tank. This is only required
for the initial setup. Note: the water level will change, this is normal.
3. Open the nearest tap downstream of the filter system (after the filter system).
4. Allow water to flow through the system slowly, and allow all air to escape out of the
closest tap. Wait until the water is flowing out of the tap and then increase the flow
slowly up to full flow. Allow to run for 5 - 10 minutes.
5. Close the opened tap and check for leaks.
6. Conduct a full manual regeneration.
7. Your system is ready for use.
Valve
(Regeneration Time: 90 mins)
This valve is factory set to regenerate every third day. The required frequency of
regeneration is dependant on the hardness level and the amount of water used. To change
the regeneration setting refer to the ‘programming’ section.
Regeneration
Start-Up
Содержание SOL-TA Series
Страница 32: ......