11
Copyright © Puretec Pty Ltd 2020
SOL-TA Commercial Series User Guide
Installation Procedure
Position the Softening System on a Level Surface
Environmental conditions
Operating temperature: 0 - 40 °C
Water conditions
Temperature:
0 - 50 °C
Pressure:
138 - 862 kPa
4
Media Installation
The Media has been shipped seperately to avoid damage in transit.
The length of the internal riser pipe is pre-set and does not need adjustment.
1.
Position the system on a flat surface close to a drain or a properly trapped
outlet, in a position when the system can service all lines requiring treated
water. The system should be placed far enough away from any water
heaters to avoid any hot water backflow into the system. A weatherproof
powerpoint and surge protector is recommended.
2. Plug or cover the top end of the riser pipe in the primary pressure tank
(labelled Vessel 1) making sure no media can enter the tube.
3. Ensure that the riser pipe is sitting in the cradle at the base of the tank.
Then using a wide mouth funnel, place the media in the tank as per the
numbering on the buckets. (Buckets are labelled Vessel 1 - Pour 1, 2, 3 etc.
Put Pour No. 1 in first, followed by 2, etc. as required).
4.
Remove the plug or cover from the riser pipe making sure you do not lift the
riser pipe. Top up tank with water.
5.
Screw the control valve onto the tank (hand tight is usually sufficient),
making sure the distributor tube is properly inserted into the valve.
6. Unscrew the head counterclockwise from the secondary pressure tank
(labelled Vessel 2).
7. Repeat the steps 2 - 4 for Vessel 2, using the buckets labelled Vessel 2 -
Pour 1, 2, 3 etc.
8. Screw the secondary head back onto the tank (hand tight is usually
sufficient), making sure the distributor tube is properly inserted into the
head.