OPERATION
Note:
Shipping restrictions for Lithium-Ion
batteries require that they
be shipped in a low state of
charge.
It may be necessary to
charge
the starting battery before normal operation.
Therefore,
is recommended to use the
manual recoil starter, when
starting
the
generator for the first time and allow
the
starting battery to recharge.
Standard Atmospheric Conditions
Ambient Temperature: 77ºF (25ºC)
Barometric Pressure: 100kPa
Relative Humidity: 30%
Generator output will vary due to changes in temperature, altitude, and humidity. If the temperature, altitude, and humidity are
higher than standard atmospheric conditions, the generator’s output will be reduced.
How to Start Engine
FOR GASOLINE:
Make sure there is gas in the tank, thenTurn fuel selector knob
to GASOLINE.
FOR LPG
: Make sure the LPG hose is safely secured from the generator to the
tank, then turn fuel selector knob to PROPANE, fully open the valve on the
propane tank.
OFF
ON
Turn battery switch ON.Choose starting method as below :
For manual start
:
Pull the recoil starter grip slowly until resistance is felt; retract, then pull rapidly
For
Push Button Start: Push and hold the One Push Start Button for no more than 1 second and release. The engine will
automatically set the choke and begin the start sequence. If it fails to start successfully, repeat this step. If it fails to start after 5
attempts, refer to the “TROUBLESHOOTING” section on page 24 of the operator’s manual
Remote Start: Push and hold start button for no more than 1 second and release
(make sure generator battery is connected)
Remote Start
START
STOP
Manual Start
or
Push Button Start
1
3
Содержание PG4500BiSRCO
Страница 25: ...WIRING DIAGRAM 25 M θ θ ...