2.6 Information for operating personnel
Operating personnel qualifications
Installation and disassembly may only be performed by a qualified specialist electrician.
Commissioning and operation must only be performed by personnel who have been trained and authorized to do
so.
Personal protective equipment
No protective equipment is required for installation, commissioning, normal operation and disassembly of the sys-
tem.
Regulations for normal operation
The operating state of the system module is displayed via the SYSTEM LED. The LED lights up orange while the sys-
tem module is starting up and changes to green (normal operation).
l
Check the following points at regular intervals:
Is there any identifiable damage on the system components and on the measuring equipment?
Are the cables crushed or damaged?
l
Rectify any defects detected immediately or report them to the operator. The system and measuring equip-
ment must only be operated in a flawless state!
l
In the event of functional faults, disconnect the system from the supply and secure it against a restart.
Operation of a machine is not impaired if the system is out of service. The machine can therefore remain in ope-
ration.