l
Possible cause
: Supply voltage parameters out of specification.
l
Remedy
: Provide suitable supply voltage.
or
l
Possible cause
: No output voltage generated by power supply unit.
l
Remedy
: Replace power supply unit.
Proceed as follows to remove the defective power supply unit:
l
Push in the locking lever and pull the power supply unit (1T1) upwards.
or
l
Possible cause
: Unknown fault on the system module.
l
Remedy
: It is not possible to troubleshoot the system module directly. In the event of a malfunction, the sys-
tem module must be sent to the manufacturer.
Proceed as follows to remove the system module:
l
Disconnect the green terminal connectors from the system module to which cables are connected.
l
Remove the system module from the top hat rail.
VIBGUARD IIoT
29
Operation