background image

 

and then display the alarming time:

 

You can also check the alarm records by SMS (Max: Latest 9 records).
SMS Check Command: Remote Control Password (Default: 1234) + [3]
Reply SMS:
Eg: Alarm record:
NO1 Zone: 05   TIME: 11-06-25 11:37
(It indicates the first record: wireless zone 5 alarm time)
…………….
NO9 Zone: 19    Time: 11-06-25 11:45
(It indicates the ninth record: wireless zone 19 alarm time)

11.GSM Signal Checking

Before  installing  the  main  unit,  you  should  check  the  signal  of  the 
installing  place  in  order  to  ensure  the  unit  can  perform  well.  In  setup 
state, input [81]     [#], the main unit will make a long beep and display 
00+XX (XX indicates the intensity of the GSM signal). And the intensity 
should  be  within  the  range  of  07-31;  if  it’s  less  than  07,  you  should 
change place.

24

23

This icon   indicates the signal intensity. When the intensity number is 
0-7,  this  icon  will  not  be  shown;  when  it’s  8-15,  this  icon  will  be 
flashing;  when  the  number  is  larger  than  16,  this  icon  will  be  on  the 
screen without flash.
For example: if the signal intensity is 12, it will display as: 

  Defense Zone       Arm         Home Arm          Type                                       Siren

Alarm 
Information

         

Zone 1

                

effective

          

invalid

           

real-time

      

Door alarm

           

yes

         

Zone 2

                

effective

          

invalid

           

real-time

      

Hall alarm

             

yes

         

Zone 3

                

effective

        

effective

         

real-time

     

Window alarm

         

yes

         

Zone 4

                

effective

       

effective

          

real-time

     

Balcony alarm

         

yes

         

Zone 5

                

effective

       

effective

          

24 hours

        

Fire alarm

            

yes

         

Zone 6

                

effective

       

effective

          

    

    Gas alarm

          

 

 

yes

24 hours

                     

effective

       

effective

         

          

                         

  

NO

24 hours

  

Emergency 
alarm

 

Emergency
button

      

Zone 7-99

         

effective

      

 

  

invalid

            

real-time

        

                        

 

  

 

yes

    

     

                     

      

effective

     

 

 

       

  

  

        

                        

   

 

 

yes

effective

24 hours

Emergency 
alarm

 

Tamper alarm
zone(99)

Emergency 
alarm

 

Program

  

 

               

8888                    Remote control                   On

 Password

   

Operation Password

               

 1234                 

         

  Siren                      

 

    Off

   

Siren sound time

                   

180 sec.               Home Appliance               Optional

   

Operating Instructions

Technical Parameters

    

     

                     

      

effective

       

 

 

invalid

       

  

  

real-time

        

                        

   

 

 

yes

Wired defense 
zone

  

95-98

Emergency 
alarm

 

 

[Technical Parameters]

Power supply: AC=220V±10%    
DC=12V (Built-in NI-HI) rechargeable battery
Standby Current: <60mA
Alarming Current: <450mA
GSM band: 850/ 900/ 1800/ 1900MHz
Wireless Frequency: 315/ 433/ 868MHz±0.5MHz
Wireless receiving sensitivity: 5mV/m
Anti-interference: 1V/m (Frequency range: 20-1000MHZ)                   
Working Temperature: 10

℃~+

40

Humidity: 

90% ( no fog)

Wireless detectors: 99pcs

Содержание Auto-dial

Страница 1: ...arm System Auto dial Intelligent GSM Auto Dial Alarm System For a better understanding of this product please read this user manual thoroughly before using it Profile Auto dial Alarm System 2013 2 V1...

Страница 2: ...of Alarm Delay 11 16 Alarm Number Setting 12 17 Delete Phone Number 12 CONTENTS 18 SMS Receiving Number Setting 12 19 Delete SMS Receiving Number 13 20 Defense Zone Programming 13 21 Home Arm Defense...

Страница 3: ...ustomized Users can make calls by using keypad on main unit just like a telephone One key control function Out Arm Home Arm Remote Arm SOS fire gas door hall window balcony and boundary places alarm R...

Страница 4: ...black cable 3 LB Positive of two way speaker red cable 4 LB Negative of two way speaker black cable 5 P1 12V output by remote control please refer to Operation Instruction part 6 GND Ground 7 P2 Linka...

Страница 5: ...indicating the remote controller succeeds in coding Operating method 20 A A indicates 1 8 remote controllers number You can add maximum 8 remote controllers LCD display 6 Delete Remote Controller The...

Страница 6: ...ssword to 2846 Operating method 31 2846 Functions Settings Functions Settings 7 8 LCD display Note the operation password and the programming password can not be set as the same number 10 Clock Settin...

Страница 7: ...ion the icon will display on the screen If turn off the function the icon will not display 10 12 Wireless Transmission Control In setup status use keypad to input 41 then input the number 1 0 and then...

Страница 8: ...input 51 56 then input the voice alarm receiving number mobile number or telephone number and then press to confirm The main unit will make a long beep the Signal indicator will flicker once and you w...

Страница 9: ...select siren on off 0 1 at last press to confirm You will hear the main unit emit a long beep and a voice prompt setting completed Operating method 60 AA B C D AA defense zone number 01 99 means zone...

Страница 10: ...ion Operating method 750 or 751 0 sound OFF system default 0 1 sound ON Example set arm disarm siren alarm sound ON LCD display 24 Siren Setting in Emergency Help Mode Press Emergency SOS button on th...

Страница 11: ...install the panel with the bracket included in the standard pack this button will be pressed down When someone is trying to disassemble the panel the button will be loosen once the bracket is taken o...

Страница 12: ...re prevention gas leak etc the alarm system will sound the alarm Press ARM button on keypad system will make a beep per second and totally 60 beeps The ARM indicator will be on without flashing It mea...

Страница 13: ...te for each number pressing it is valid only you hear a DI confirmation sound Please reenter it if you do not hear the sound And sometimes for weak gsm signal you need to input for several times 9 Sys...

Страница 14: ...intensity is 12 it will display as Defense Zone Arm Home Arm Type Siren Alarm Information Zone 1 effective invalid real time Door alarm yes Zone 2 effective invalid real time Hall alarm yes Zone 3 eff...

Страница 15: ...ork normally Check the wireless detectors once a month 1 Trigger wireless detectors to see if system can alarm normally 2 Check all detectors batteries to see if it s in low voltage 3 Check whether wi...

Страница 16: ...es Number 01 99 30 password Change Operation Password Default 1234 31 password Change Program Password Default 8888 32 AA BB CC DD EE FF System Time Setting AA year BB month CC date DD hour EE minute...

Страница 17: ...in Emergency Helpmode 0 off default 1 on 77 1 0 SMS Notification for Arm Disarm 81 GSM Signal Checking Intensity 07 31 if its less than 07 you should change place 83 0 1 Arm Disarm Voice Prompt 0 off...