Function Setting Commands
29
[
51]~[56] + [#]
Delete Phone Number
[
57]~[59] + Phone
[#]
SMS Receiving
Number Setting
3 groups of SMS receiving number
[
57]~[59] + [#]
Delete SMS Receiving
Number
[
60] + [AA] + [B] +
[C] + [D] + [#]
Defense Zone
Programming
AA: Defense zone number: [01
乣
99]
B: Defense zone type: [1]real-time;
[2] 40 seconds delay; [3]24 hours;
[4] bypass
C: Defense zone location: [1]SOS
Alarm; [2] Fire Alarm; [3]Gas Leak
Alarm; [4]Door Alarm; [5]Hall Alarm;
[6]Window Alarm; [7]Balcony Alarm;
[8]Boundary Alarm
D: Siren ON/OFF
[0] OFF, [1] ON
[
61] + [01~12] +
[0/1] + [#]
Home Arm Defense
Zone Setting
Defense zone number: 01~12;
[0] Home arm but not alarm;
[1] Home arm and alarm
[
70] + [1] + [#]
Voice Recording
10 seconds
[
75] + [0/1] + [#]
Siren Setting
[
0]: off (default); [1]: on
[
76] + [0/1] + [#]
Siren Setting in
Emergency Help mode
[
0]: off (default); [1]: on
[
77] + [1/0] + [#]
SMS Notification for
Arm/ Disarm
[
81] + [#]
GSM Signal Checking
Intensity: 07-31 (if its less than 07,
you should change place.)
[
83] + [0/1] + [#]
Arm/ Disarm
Voice Prompt
[
0]: off; [1]: on (default)
[
84] + [0/1] + [#]
Voice Prompt for
All Settings
[
0]: off; [1]: on (default)
[
88] + [#]
IMEI Checking
[*] + [
0] + [#]
Alarming Record
Checking
Press 2: upturn
Press 8: downturn
Press [*#]: Exit
30
Function Setting Commands
[
95175308246] + [#] Factory Reset Use with caution
[
operation
password] + [1]
Arm by SMS
Default operation password: 1234
[
operation
password] + [2]
Disarm by SMS
[
operation
password] + [3]
Alarm Record
Checking by SMS
Default operation password: 1234
Default operation password: 1234
Note:
the last five functions could be realized only when the GSM
signal intensity reaches 20.
[
operation
password] + [4]
Turn on 12V output
Default operation password: 1234
[
operation
password] + [5]
Turn off 12V output
Default operation password: 1234