background image

Components List

26

25

Care and Maintenance

[Components List]

Main panel                                        1pc, 
Remote controller                             2pcs,
Siren                                                 1pc,
Wireless PIR sensor                         1pc, 
Wireless Door sensor                       1pc, 
Power adapter (DC 12V/1.2A)          1pc, 
Back-up battery                                1pc
User manual                                     1pc. 

[Care and Maintenance]

The  alarm  system  has  excellent  design  and  uses  advanced 
technologies. It shall be used with care. The following suggestions are 
required to maintain your obligations under the warranty terms, and for 
prolonging the service life of the system.
      Place  the  control  panel  and  all  parts  and  accessories  out  of 

children’s reach.

      Keep  the  alarm  system  dry.  Rain,  humidity  and  various  fluids  or 

moisture all will corrupt the electronic circuit.

        Do  not  use  or  place  the  alarm  system  in  dirty  locations,  otherwise 

the electronic elements will be damaged.

    Do  no  place  the  system  in  excessively  hot  locations.  High 

temperature  will  shorten  the  service  life  of  electronic  equipment, 
damage batteries, deform or even melt some plastic parts.

    Do  not  place  the  system  in  excessively  cold  locations.  Otherwise 

condensation  many  occur  and  damage  the  circuit  board  of  the  alarm 
system.

   

It  is  recommended  that  you  check  and  test  the  alarm  system 

periodically:

Check the main unit every three months:
1.Whether it can arm/disarm normally;
2.Whether it can dial the number for alarm normally;
3.Whether it can receive wireless detectors’ signal normally;
4.Whether the back-up battery can work normally.
Check the wireless detectors once a month:
1.Trigger wireless detectors to see if system can alarm normally;
2.Check all detectors’ batteries to see if it’s in low voltage;
3.Check whether wireless detectors can send signal to the main unit normally.

Check the SIM card:
1.Check the use of SIM card, such as network signal, balance, etc.
2.Make sure the PIN code verification of the SIM card is closed.
3.Please  keep  the  password  and  SIM  card  number  safe,  in  case  that 
other people remote control the system illegally.
   Since  the  alarm  system  is continuously  in operation or standby 
mode, the supply adaptor of the control panel shall be connected to a 
safe and reliable socket.
   Do not place the system near your bedroom or office table, because 

the siren will make high-loudness sound in the case of alarm, which 
may adversely affect your rest or work.

      If    the    alarm    system    will    not  be    used  for  a  long  time  ,  please 

disconnect the system from the power supply.

    Please  do  not  disassemble,  repair  or  alter  the  products  without 

permission, or it may cause accidents and faults.

    Do not drop this product on the ground or on hard objects, as it may 

lead to massive impact to cause faults and damages.

   Without approval and consent of relevant authorities, please do not 

set “110”, “119” or the alarm phone number of police station for this 
main unit.

Please read the suggestions above carefully and follow the instructions 
herein. If any of the equipment does not work properly, please send it 
to the dealer or authorized service point for repair. We will try our best 
to solve the problem for you as soon as possible.

Содержание Auto-dial

Страница 1: ...arm System Auto dial Intelligent GSM Auto Dial Alarm System For a better understanding of this product please read this user manual thoroughly before using it Profile Auto dial Alarm System 2013 2 V1...

Страница 2: ...of Alarm Delay 11 16 Alarm Number Setting 12 17 Delete Phone Number 12 CONTENTS 18 SMS Receiving Number Setting 12 19 Delete SMS Receiving Number 13 20 Defense Zone Programming 13 21 Home Arm Defense...

Страница 3: ...ustomized Users can make calls by using keypad on main unit just like a telephone One key control function Out Arm Home Arm Remote Arm SOS fire gas door hall window balcony and boundary places alarm R...

Страница 4: ...black cable 3 LB Positive of two way speaker red cable 4 LB Negative of two way speaker black cable 5 P1 12V output by remote control please refer to Operation Instruction part 6 GND Ground 7 P2 Linka...

Страница 5: ...indicating the remote controller succeeds in coding Operating method 20 A A indicates 1 8 remote controllers number You can add maximum 8 remote controllers LCD display 6 Delete Remote Controller The...

Страница 6: ...ssword to 2846 Operating method 31 2846 Functions Settings Functions Settings 7 8 LCD display Note the operation password and the programming password can not be set as the same number 10 Clock Settin...

Страница 7: ...ion the icon will display on the screen If turn off the function the icon will not display 10 12 Wireless Transmission Control In setup status use keypad to input 41 then input the number 1 0 and then...

Страница 8: ...input 51 56 then input the voice alarm receiving number mobile number or telephone number and then press to confirm The main unit will make a long beep the Signal indicator will flicker once and you w...

Страница 9: ...select siren on off 0 1 at last press to confirm You will hear the main unit emit a long beep and a voice prompt setting completed Operating method 60 AA B C D AA defense zone number 01 99 means zone...

Страница 10: ...ion Operating method 750 or 751 0 sound OFF system default 0 1 sound ON Example set arm disarm siren alarm sound ON LCD display 24 Siren Setting in Emergency Help Mode Press Emergency SOS button on th...

Страница 11: ...install the panel with the bracket included in the standard pack this button will be pressed down When someone is trying to disassemble the panel the button will be loosen once the bracket is taken o...

Страница 12: ...re prevention gas leak etc the alarm system will sound the alarm Press ARM button on keypad system will make a beep per second and totally 60 beeps The ARM indicator will be on without flashing It mea...

Страница 13: ...te for each number pressing it is valid only you hear a DI confirmation sound Please reenter it if you do not hear the sound And sometimes for weak gsm signal you need to input for several times 9 Sys...

Страница 14: ...intensity is 12 it will display as Defense Zone Arm Home Arm Type Siren Alarm Information Zone 1 effective invalid real time Door alarm yes Zone 2 effective invalid real time Hall alarm yes Zone 3 eff...

Страница 15: ...ork normally Check the wireless detectors once a month 1 Trigger wireless detectors to see if system can alarm normally 2 Check all detectors batteries to see if it s in low voltage 3 Check whether wi...

Страница 16: ...es Number 01 99 30 password Change Operation Password Default 1234 31 password Change Program Password Default 8888 32 AA BB CC DD EE FF System Time Setting AA year BB month CC date DD hour EE minute...

Страница 17: ...in Emergency Helpmode 0 off default 1 on 77 1 0 SMS Notification for Arm Disarm 81 GSM Signal Checking Intensity 07 31 if its less than 07 you should change place 83 0 1 Arm Disarm Voice Prompt 0 off...

Отзывы: