Back cover schematic diagram:

 Wired ports:

Function Settings

3

4

Tamper Alarm Button

Power Switch

Lead Wire Slot

PCB

Fix Bracket 

DC 12V Input

SIM Card Socket

Wired Ports

S

P

K

+

S

P

K

-

L

B

+

L

B

-

G

N

D

P

2

Z

1

G

N

D

G

N

D

Z

3

Z

4

P

1

Z

2

G

N

D

G

N

D

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

1     SPK+      Positive of siren (red cable)

2

     

SPK-

       

Negative of siren (black cable)

3

     

LB+

         

Positive of two-way speaker (red cable)

4

     

LB-

          

Negative of two-way speaker (black cable)

5

     

P1

           

12V output by remote control. (please refer to Operation Instruction part)

6

     

GND

       

Ground 

7

      

P2

          

Linkage output port 2. There will be 12V output once the system is 

                      armed, and be off once it’s disarmed.

8

      

GND

      

Ground

9

      

Z1

           

Wired sensor 1 (zone number: 95)

10

   

GND

       

Ground

11

    

Z2

           

Wired sensor 2 (zone number: 96)

12

   

GND

       

Ground

13

   

Z3

           

Wired sensor 3 (zone number: 97)

14

   

GND

       

Ground

15

   

Z4

           

Wired sensor 4 (zone number: 98)

Alarm Host Diagram

Содержание Auto-dial

Страница 1: ...arm System Auto dial Intelligent GSM Auto Dial Alarm System For a better understanding of this product please read this user manual thoroughly before using it Profile Auto dial Alarm System 2013 2 V1...

Страница 2: ...of Alarm Delay 11 16 Alarm Number Setting 12 17 Delete Phone Number 12 CONTENTS 18 SMS Receiving Number Setting 12 19 Delete SMS Receiving Number 13 20 Defense Zone Programming 13 21 Home Arm Defense...

Страница 3: ...ustomized Users can make calls by using keypad on main unit just like a telephone One key control function Out Arm Home Arm Remote Arm SOS fire gas door hall window balcony and boundary places alarm R...

Страница 4: ...black cable 3 LB Positive of two way speaker red cable 4 LB Negative of two way speaker black cable 5 P1 12V output by remote control please refer to Operation Instruction part 6 GND Ground 7 P2 Linka...

Страница 5: ...indicating the remote controller succeeds in coding Operating method 20 A A indicates 1 8 remote controllers number You can add maximum 8 remote controllers LCD display 6 Delete Remote Controller The...

Страница 6: ...ssword to 2846 Operating method 31 2846 Functions Settings Functions Settings 7 8 LCD display Note the operation password and the programming password can not be set as the same number 10 Clock Settin...

Страница 7: ...ion the icon will display on the screen If turn off the function the icon will not display 10 12 Wireless Transmission Control In setup status use keypad to input 41 then input the number 1 0 and then...

Страница 8: ...input 51 56 then input the voice alarm receiving number mobile number or telephone number and then press to confirm The main unit will make a long beep the Signal indicator will flicker once and you w...

Страница 9: ...select siren on off 0 1 at last press to confirm You will hear the main unit emit a long beep and a voice prompt setting completed Operating method 60 AA B C D AA defense zone number 01 99 means zone...

Страница 10: ...ion Operating method 750 or 751 0 sound OFF system default 0 1 sound ON Example set arm disarm siren alarm sound ON LCD display 24 Siren Setting in Emergency Help Mode Press Emergency SOS button on th...

Страница 11: ...install the panel with the bracket included in the standard pack this button will be pressed down When someone is trying to disassemble the panel the button will be loosen once the bracket is taken o...

Страница 12: ...re prevention gas leak etc the alarm system will sound the alarm Press ARM button on keypad system will make a beep per second and totally 60 beeps The ARM indicator will be on without flashing It mea...

Страница 13: ...te for each number pressing it is valid only you hear a DI confirmation sound Please reenter it if you do not hear the sound And sometimes for weak gsm signal you need to input for several times 9 Sys...

Страница 14: ...intensity is 12 it will display as Defense Zone Arm Home Arm Type Siren Alarm Information Zone 1 effective invalid real time Door alarm yes Zone 2 effective invalid real time Hall alarm yes Zone 3 eff...

Страница 15: ...ork normally Check the wireless detectors once a month 1 Trigger wireless detectors to see if system can alarm normally 2 Check all detectors batteries to see if it s in low voltage 3 Check whether wi...

Страница 16: ...es Number 01 99 30 password Change Operation Password Default 1234 31 password Change Program Password Default 8888 32 AA BB CC DD EE FF System Time Setting AA year BB month CC date DD hour EE minute...

Страница 17: ...in Emergency Helpmode 0 off default 1 on 77 1 0 SMS Notification for Arm Disarm 81 GSM Signal Checking Intensity 07 31 if its less than 07 you should change place 83 0 1 Arm Disarm Voice Prompt 0 off...

Отзывы: