26.Arm/ Disarm Voice Prompt
This product has this function: when you arm/ disarm it, it will give
voice prompt “system armed/ disarmed”. You can deactivate it if you do
not need.
In setting status, first input [83], then [0/1] and finally press [#] to
confirm. The main unit will make a long beep and voice prompts:
setting completed, please enter instruction.
Operating method: [83] [0/1] [#]
[1]: activate voice prompt for arm/ disarm (factory default)
[0]: deactivate voice prompt for arm/ disarm
For example: Set arm/disarm voice prompt OFF
Operating method: [83] [0] [#]
27.Voice Prompt for All Settings
For all above settings, you could hear the voice prompt such as
“setting completed, please enter instruction”, “delete completed”. You
can deactivate the voice if you do not need them.
In setting status, first input [84], then [0/1] and finally press [#] to
confirm. The main unit will make a long beep and voice prompts:
setting completed, please enter instruction.
Operating method: [84] [0/1] [#]
[1]: activate voice prompt for all operations (factory default)
[0]: deactivate voice prompt
For example: Set voice prompt OFF
Operating method: [84] [0] [#]
Note: after you deactivate this function, all the voice including arm/
disarm voice will not work.
28.Tamper Alarm Setting
There is a tamper alarm button at the back side of the panel. If you
install the panel with the bracket (included in the standard pack), this
button will be pressed down. When someone is trying to disassemble
the panel, the button will be loosen once the bracket is taken off and
the system will make alarm at the same time.
In setting status, first input [87], then press [0/1] and finally press [#] to
confirm. The main unit will make a long beep and voice prompts:
setting completed.
Operating method:
【
87
】 【
0/1
】 【#】
[
0]: Tamper alarm OFF (factory default)
[1]: Tamper alarm ON
For example: Set Tamper alarm ON
Operating method:
【
87
】 【
1
】 【#】
Note: The alarm SMS is “zone 99 emergency alarm"”.
29.IMEI Checking
In setting status, first input [88] and then press [#] to confirm. The 15-
digit IMEI code will be displayed separately in 4 pages (2 seconds per
page) on the screen.
30.SMS Notification for Power Failure/ Recovery
In Out Arm status, if the main panel is powered off, the built-in battery
will supply power, and main unit will send SMS (power charger off) to
all the three preset SMS-receiving numbers.
In Out Arm status, if the main panel recovers power, it will send SMS
(power charger on) to all the three SMS-receiving numbers.
While in Disarm or Home Arm status, it does not have this function.
[Operation Instructions]
1.System status. There are 4 statuses as following:
Arm: defense zone 1~99 will alarm when detectors are triggered
Home Arm: in arm status, the defense zone which is set as [Home
Arm] will alarm when detectors are triggered.
17
18
Functions Settings
Functions Settings