33
Bit
Weight Cassette Number
1
+1
Cassette 1 (PBX)
2
+2
Cassette 2 (satellite)
3
+4
Cassette 3 (satellite)
4
+8
Cassette 4 (satellite)
5
+16
Cassette 5 (satellite)
6
+32
Cassette 6 (satellite)
7
+64
Cassette 7 (satellite)
8
+128
Local keyboard (generating event)
Table 8 Assignment of bitmask to individual keyboards
10.9.
Program A-0
–
restoring default settings
This subprogram is used to reset the system settings. After entering the subprogram, the cassette
will display a message
◼⧫
. Then enter the code of required operation (see table 20). After
entering the action code, the cassette will display
and wait for the installer code. After
entering the installer code, the selected settings will be reset to zero.
Note!
To reset the settings, it is necessary to set your own installer code. Default code
“
0000
”
does not enable to delete parameters.
Number
Resetting
0
Global settings
1
Local settings of PBX cassette
2-6
Local satellite settings
10
All global and local settings
11
Local settings of all keyboards (including PBX)
20
Deletion of all A-1, A-2 and A-3 entries
91
Copying lock codes from MCD1803
99
Deletion of IDs assigned to the property (program A-1)
Table 9Program options A-0