34
Note!
Resetting the settings is understood as:
•
restoring the default value in case of global setting
•
deletion of field value in case of local value
The installer code is not deleted.
Function 99 (deleting A-1 program entries) requires the installer code. After authorization, the
cassette will display
–
enter the number of premises from which IDs are to be deleted
and confirm with button
.
10.9.1.
Copying MCD1803 memory
Available from software version 9r23.60
An adapter is required for copying, available to purchase from the Proel store. Place the memory
removed from mcd1803 in the adapter slot in the correct direction (as indicated on the tray). Then
place the adapter in KDC39XX keyboard in a USB communication connector.
Note!
The data copying procedure can be carried out remotely (for BM0900 it is the only
possibility)
–
the data is transferred to the control panel where the programming menu is started
(see chapter 10.1)
After entering the programming, select program A-0, select subprogram 91 and accept with
button
, then enter the installer code. The keyboard will start to analyze the connected
memory
–
based on the codes entered, the number and year of the code table is displayed. After
the analysis is completed, the keyboard will display the corresponding data alternately. If the
installer does not react, the data will be entered in parameters 208 and 209 of the control panel.
This program will also rewrite all the changed lock codes, overwriting those already present (as in
A3 procedure). The remaining codes are generated by the code table generator and are not
physically saved in the control panel (see chapter
Błąd! Nie można odnaleźć źródła
odwołania.Błąd! Nie można odnaleźć źródła odwołania.
).
The procedure should be repeated for other control panels in the system (if they are to share the
database), or rewrite the number and year of the code table, or use the possibility to dump the
data on microSD card (see chapter 10.6Program A6
10.10.
Autobackup
Autobackup function is used to protect data entered into the cassette. The cassette automatically
saves data on the microSD card in the same format as with normal recording (see section 10.6).
The recording is called up when leaving the programming menu (if any changes have been made).
Subsequent backup files have successive names from BAK0.CSV to BAK9.CSV, where BAK0.CSV is
the newest file and BAK9.CSV the oldest.
Reading data from the backup file is possible by program A-6 and function 4 (see section 10.6).
The keyboard will display a message
–
then enter the number of the file to be read and
accept with button
. In case of successful operation, the cassette will signal a message
, while an error (usually no file) will be indicated by a message
.
NOTE: From software 9r23.24 autobackup is saved in XML format.