60 PRODIGIT
3.5.4. AUTO-SEQUENCE
An auto-sequence allows the user to step through previously saved set-ups stored in
The mainframe’s memory. Up to 9 auto-sequences can be saved. Each auto-
Sequence can consist of up to 16 steps. There are two modes in the auto-sequence
Function. These are edit mode and test mode.
3.5.4.1 Edit Mode
1. Press EDIT key, then EDIT button will become lit and the LCD will display "FX-
XX". This is defined as follows:
The “FX” part indicates the auto-sequence number (F1 to F9 are possible). The
Numbered STATE keys are Used to select the auto-sequence numberThe “XX”
Part is the test step (1 to 16 is possible).
2. Once the auto-sequence number has been selected the Memory location of the
First test step can be selected. The Arrow keys next to the 3350F LCD are used to
Select the Memory BANK and Memory STATE.
Once the desired location has been selected press ENTER next the total test time
For that step (T1+T2) can be entered.
T1 is the test time without checking the NG/LIMIT settings.
T2 is the test time where if NG is ON the LIMIT settings will be checked. The
Upper arrow keys are used to set T1 and the lower arrow keys are used to set T2.
The time setting can be adjusted in the range of 0.1s to 9.9s in 100ms Increments.
Please see sections 3.2.7 and 3.2.8 for a definition of T1 and T2.