30 PRODIGIT
3.2.11. Key and LED
The 3350F series Load Module features 2 setting ranges for CC, CR, CV & CP
Operation. This allows improved resolution for setting low values. When left in the
Default AUTO mode the changeover between ranges is automatic depending on
The setting value entered.
If desired the RANGE button can be pressed to force the unit to operate only in
RANGE II. This is signaled by the accompanying LED becoming lit. Please note
That it is only possible to force RANGE II in CC mode.
Note: Coercion Range II only in CC Mode.
3.2.12. Key and LED
The LEVEL button is used to program a High or Low load value. The setting value
Changes between current, resistance, voltage or power depending whether CC, CR,
CV or CP mode has been selected. If the LED is lit then the High level value setting
Has been enabled. If the LED is not lit then the low load level can be set using the
Rotary switch in combination with the arrow keys.
In STATIC mode the user can switch between High and low load levels during
Operation.
In DYNAMIC operation (CC & CP modes only) the preset high and low levels are
Used to define the dynamic
waveform.
Please note that the low level setting cannot exceed the high level. The converse is
Also true in that the High level cannot be set below the low level.
3.2.12.1 In Constant Current mode:
The level is initial setting on High, LEVEL High / Low has two level, Low
Current level setting must be lower than Level High.
3.2.12.2 In Constant Resistance mode:
The level is initial setting on High, LEVEL High / Low has two level, Low
Resistance level setting must be lower than Level High.
P.S.
:
CR Mode Level High / Low level by current perspectives.
3.2.12.3 In Constant Voltage mode:
IF Low level load voltage value greater than High level load voltage value
or opposite status
,
the load voltage value is equal.
P.S.
:
CV Mode Level High / Low has "automatic push function".
3.2.12.4 In Constant Power mode:
The level is initial setting on High, LEVEL High / Low has two level, Low
Power level setting must be lower than Level High.
Range