2.4 INPUTS
2.4.1 Digital Inputs
Number
8 fully configurable
Arrangement
Connection to Ground
Polarity
Programmable as Normally Open or Closed
Low Level Threshold
<0.7 V
Max Input Voltage
+40V
Min Input Voltage
-40V
Contact Wetting Current
1ma
Open Circuit Voltage
3V
2.4.2 Analog Input
2.4.2.1 Coolant Temperature and Fuel
Measurement Type
Resistance measurement by measuring voltage across sensor with
a fixed current applied
Arrangement
Differential resistance measurement input
Measurement Current
13 mA independent of System Voltage
Full scale
600 Ohms
Resolution
Fuel 1%
Temperature 1°
Accuracy
<1% of Full scale ± 4 Ω excluding transducer errors
Max Common Mode
Voltage
0.5V
Display Range
Depends upon the sensor selected.
(Sensor can be selected from pre-programmed sensors or user can
program sensor data)
2.4.2.2 Pressure Sensor
: Resistive type sensors or 4-20mA sensor interface
Measurement Type
Programmable
Resistance measurement by measuring voltage across
sensor with a fixed current applied
4-20 mA output sensors
Arrangement
Resistive
: Differential resistance measurement input
4-20 mA
: Burden of 100 Ω
Measurement Current
Resistive
: 13 mA independent of System Voltage
Full scale
600 Ohms
Resolution
0.1 bar
Accuracy
Resistive :<
1% of Full scale ± 4 Ω excluding transducer errors
4-20mA: 2% of full scale excluding transducer error
Max Common Mode Voltage 0.5V
Display Range
Depends upon the sensor selected.
(Sensor can be selected from pre-programmed sensors or user can
program sensor data for resistive sensor)