6.3.4 Command ControlLedOn()
This command turns on one of the two control LEDs. The second red LED is not installed.
ControlLedOn(SerialNo, TID, LED)
OP-Code: 48
Parameter:
SerialNo
9-digit serial number with preceding blank
TID
2 characters transaction number of the host
LED
Bool value:
0 = green LED
1 = optional red LED
Return string:
SerialNo
9-digit serial number with preceding blank
TID
2 characters transaction number
6.3.5 Command ControlLedOff()
Turns off one of the two control LEDs. The second, red LED is not installed.
ControlLedOff(SerialNo, TID, LED)
OP-Code: 52
Parameter:
SerialNo
9-digit serial number with preceding blank
TID
2 characters transaction number of the host
LED
Boolean value:
0 = green LED
1 = optional red LED
Return string:
SerialNo
9-digit serial number with preceding blank
TID
2 characters transaction number
Содержание ZEHNTNER ZGM1120