10
Date:
20-11-2014
Data name:
esc300-2-v12a_EN
ESC300 (swv-1.06)
Author:
Heiko Lange
Pages:
72
© P. Prinzing GmbH - 89173 Lonsee-Urspring (Germany)
Service: +49 (0) 7336 - 961018
* Option / depends on design
Assembling and connection
2.
Assembling and connection
INFO
Consider during the assembling, that there is a stable radio connection between the
control and the Charge with the remote.
The radio connection depends on the environment of the system. Armoured concrete
walls, metal matrix, steel beams, fodder mixing wagons or other obstacles might attenuate
the signal!
Consider the following points when mounting the components (equipment).
- Mount the control on a central, accessible place on a level surface.
- Into the feed line has to be mounted a main switch in a striking distance to the control.
- The charge module with the remote can be mounted independent to the position of the control ESC300 (e.g. in the
stall).
- Mount the external radio module as central as possible in the operation area of the dung removal system, in a height
of min. 2,5 m. Armoured concrete walls and metal structures might attenuate the signal!
- The equipment should not be exposed to extremely heat, cold or extreme thermal fl uctuations.
- Protect the equipment of splash water or direct insolation.
- Mount all necessary screwing (enclosed) and close after assembling all coverings and not used openings on the
equipment.
- If it is possible, mount the emergency stop button unapproachable for the animals (possible errors), viewable and ac-
cessible. According to the local conditions, you have to mount several emergency stop buttons.
- Use only allowed cables and lines and do not exceed the maximum length of the lines.
- Remove the battery protection fi lm on the backside of the
REMOTE
before fi rst using (pull the protection fi lm out of
the battery case!)
2.1. Assembling the control ESC300
Mount the control ESC300 by the delivered mounting straps (fi g. 10/2) on a fi rm
surface. Insert the cable only from the bottom of the control.
Connect on the control ESC300:
- Power feed line (400 V / 3~/PE, from the main switch).
- External radio module
- Motors rope winches for alley 1 - 3
- Emergency stop buttons
- Temperature sensor
- External push buttons* for alley 1 - 6
- End switch* (mechanical or inductive) for alley 1 - 3
- Contact for error messages*
- Contact for cross transport*
10/1
ESC300
Measurements: 400 x 300 x 180 mm
10/2
Mounting strap