Programming Product Name and Water Cycle (continued)
A. Press the UP or DOWN Arrow button to change the valve
OFF time.
B. Press the RAPID STEAMER LOGO button to store the new
valve OFF time.
NOTE: Pressing the PRODUCT 3 button at any time exits the
Program Mode without storing the change.
8
A. Press the UP or DOWN Arrow button to change the number
of water cycles.
B. Press the RAPID STEAMER LOGO button to store the new
water cycle number.
NOTE: Pressing the PRODUCT 3 button at any time exits the
Program Mode without storing the change.
10
Platen temperature can be set between 129° – 176°C
(265° – 350°F).
A. Press the UP or DOWN Arrow button to scroll to the desired
temperature.
B. Press the RAPID STEAMER LOGO button to store the desired
temperature.
NOTE: Pressing the PRODUCT 3 button at any time exits the
Program Mode without storing the change.
12
Factory Pre-Set Temperatures
625-MCD Factory pre-set temperatures:
Filet: 151°C (305°F)
Large: 151°C (305°F)
PROD1 – 12: 151°C (305°F)
625-MFY Factory pre-set temperatures:
Filet: 176°C (350°F)
Large: 176°C (350°F)
PROD1 – 12: 176°C (350°F)
The display now shows the product’s number of on-off water
valve cycles.
9
The display now shows the current product set temperature.
11
2.5
The display now shows the time delay between when the
product is finished and when the alarm sounds.
The delay can be set for 0.0 to 10.0 seconds.
A. Press the UP or DOWN Arrow button to scroll to the desired
time delay.
B. Press the RAPID STEAMER LOGO button to store the
desired time and to exit the Program Mode.
NOTE: Pressing the PRODUCT 3 button at any time exits the
Program Mode without storing the change.
13
Error Messages
Error Messages
Action
No Heat Error.
Call service technician.