Steamer
625-MCD & MFY
Temperature Calibration
A. Press and hold the TEMPERATURE button. The display will
show the current temperature setting for Celsius (C) or
Fahrenheit (F).
B. While holding the TEMPERATURE button, press the C/F
button to change the setting between Fahrenheit and Celsius.
C. Release the TEMPERATURE button to store the new value.
1
A. Press the UP or DOWN Arrow button until the temperature
readout matches the calibration reading.
B. Press the RAPID STEAMER LOGO button to store the desired
calibration and exit CAL TEMP Mode.
NOTE: Pressing the PRODUCT 3 button at any time exits the
Program Mode without storing the change.
3
View Firmware Version
Press and hold the RAPID STEAMER LOGO button first, then press
and hold the START button. The display will show the current firmware
version.
. VERS XX.XX
The CAL TEMP Mode is used to calibrate the platen temperature
with an external meter connected to the meter plug inlet on the
bottom right side of the unit. Add ± 5°C (± 10°F).
2
A. Press and hold RAPID STEAMER LOGO button and immediately
press and hold the TEMPERATURE button. Hold for 6 seconds.
B. The display now shows the current calibration temperature.
C. Press the PRODUCT 2 button to zero any previous calibration offset
value. The display will now show the platen temperature without any
calibration offset.
Factory Presets
Loading factory presets restores the unit to factory settings and voids
all user programmed information.
A. During power up, press and hold both PRODUCT 1 and
PRODUCT 4 buttons within 3 seconds. The display will flash
PRESETS LOADED.
B. Release both buttons.
625-MCD
Default Factory Presets:
ON OFF Cycles Delay
1.5
3.0
2
2.5
625-MFY
Default Factory Presets:
ON OFF Cycles Delay
0.5
1
6
2.5
Manual Reset
A hi-limit thermostat will turn off electrical power to the platen and
control circuits if the unit overheats.
Turn the unit off and allow to cool (approximately 10 – 15 minutes).
A manual reset is located on the back of the unit. Once the unit has
cooled sufficiently, remove the cap and press the manual reset and
restart the unit. Replace the manual reset cap.
NOTE: If the unit continues to shut off due to overheating, contact your
authorized Prince Castle Service Agency.
Manual
Reset