Prince Castle 625-MCD Скачать руководство пользователя страница 12

Printed in U.S.A. 1/06 © 2006

12

625-505revI-EN

Steamer
625-MCD & MFY

Water Tube Cleaning

In areas that have very hard water conditions, scale can accumulate in the water tube, preventing proper water dispensing. Thus, the water tube should 
be cleaned during the deliming process as well as during the daily cleaning. It is recommended that the steamers go through a deliming procedure once 
a month. Some hard water areas may require daily, weekly, or biweekly deliming based on actual buildup.

Turn unit off and unplug the power cord from the electrical 
receptacle. Proceed with caution. The unit is still hot.

Items needed:

— McDonald’s Delimer

— Insulated gloves

— Steamer brushes

WARNING

Immediately after turning off the unit, prepare the deliming 
solution. Add one packet of McD Delimer to 16 ounces of warm 
water. To ensure that all of the delimer dissolves, stir solution 
vigorously. Remove top cover, venturi plate, spatula and top plate.

These pieces are hot.

Pour the Delimer into the steam chamber.

WARNING

1

Let solution soak on the platen for five minutes.

While deliming the platen, dampen the bristles of the brush by 
dipping it in delimer solution.

2

Insert and remove the steamer brush into and out of the water 
tube to disintegrate any scale build up in the tube. Insert the 
pipe cleaner at least 1 inch into the tube.

Repeat for 30 seconds.

The platen is still hot!

CAUTION

3

If the tube is severely clogged, the tube will need to be removed 
from the unit and replaced. Refer to Water Tube Replacement 
instructions.

4

Содержание 625-MCD

Страница 1: ...e Inc without cost to the customer for parts or labor This warranty covers on location service i e trip charges and or mileage Travel mileage is limited to 100 miles 200 kilometers round trip one trip...

Страница 2: ...s unit the ambient temperature at the mounting site should not exceed 37 8 C 100 F All electrical connections must be in accordance with local electrical codes and any other applicable codes Plug the...

Страница 3: ...Press and hold RAPID STEAMER LOGO button and immediately press and hold the TEMPERATURE button Hold for 6 seconds B The display now shows the current calibration temperature C Press the PRODUCT 2 but...

Страница 4: ...cter D Press the RAPID STEAMER LOGO button to store the new product name NOTE Pressing the PRODUCT 3 button at any time exits the Program Mode without storing the change 4 A Press the UP or DOWN Arrow...

Страница 5: ...tore the desired temperature NOTE Pressing the PRODUCT 3 button at any time exits the Program Mode without storing the change 12 Factory Pre Set Temperatures 625 MCD Factory pre set temperatures Filet...

Страница 6: ...ustralia only McD Delimer as required Clean sanitized towel Protective insulated gloves A Remove spatula B Remove the top plate by carefully sliding it forward and out of the unit C Remove the venturi...

Страница 7: ...ves A Remove spatula B Remove the top plate by carefully sliding it forward and out of the unit C Remove the venturi plate While wearing protective gloves 2 Top Plate Venturi Plate Spatula 4 Pour a so...

Страница 8: ...lve Assembly 13 625 318S Water Connector Kit 14 65 059S Relay 625 MFY 65 061S Relay 625 MCD 625 MCDA 625 MCDA16 15 625 323S Main Power PCB 16 625 065S Venturi Plate 17 625 082S Temperature Probe 1000...

Страница 9: ...to between 20 and 30 psi Water ON cycle too long Check for proper programming of Filet steam cycles Decrease ON time until desired results are reached Too many water cycles Check for proper programmi...

Страница 10: ...Printed in U S A 1 06 2006 10 625 505revI EN Steamer 625 MCD MFY Wiring Diagram...

Страница 11: ...Sanitizer Let air dry Wipe steam chamber with sanitized cloth Wipe down all external surfaces with McD ASPC APC Use steamer brush to clean the water tube Monthly Delime the steam chamber NOTE Dependi...

Страница 12: ...amer brushes WARNING Immediately after turning off the unit prepare the deliming solution Add one packet of McD Delimer to 16 ounces of warm water To ensure that all of the delimer dissolves stir solu...

Страница 13: ...end of valve 2 Using pliers gently pull the tube out from the platen You may need to softly rock it back and forth Replace the black insulating bushing if the original bushing pulled out with the wate...

Страница 14: ...t the shorter end of T Connect to the steamer whose regulator is closest to the inlet water line T Connect s female end to steamer s male end 1 Place the long end of the T Connect tubing in between th...

Страница 15: ...625 505revI EN 15 Printed in U S A 1 06 2006 Steamer 625 MCD MFY Notes...

Страница 16: ...with McD Sink Pak Sanitizer KAYQUAT and air dry 3 Wipe the steam chamber surface with a clean sanitized towel 4 If the surface shows signs of excessive calcium and lime buildup dissolve two teaspoons...

Страница 17: ...kly cleaning partial packets can be used Two teaspoons of McD Delimer can be dissolved in a small coffee cup with hot water The packet can be used for 4 applications However it is not recommended to l...