AIR 40, AIR Breeze, AIR 30, AIR X MARINE and AIR SILENT-X are trademarks of Primus Wind Power 2013 Primus Wind Power Inc.
AIR Owner’s Manual
3-CMLT-2020-A
5
AIR Technical Specifications
Model
AIR 40 and AIR Breeze
Weight
13 lb. / 5.9 kg
Rotor Diameter
46 in / 1.17 m
Start Up Wind Speed
7 mph (3.13 m/s)
Kilowatt Hours/month 40 kWh/month @ 12 mph ( 5.5 m/s)
Max. Wind Speed
110 mph (49.2 m/s)
Rated Power
160 watts @ 28 mph (12.5 m/s)
Operating Temperature Range:
AIR Breeze and AIR 40 are certified under
IEC requirements applying to the temperature range 14° F / (-10° C) to 104º F
(40° C). AIR 40 is CSA. IEC & CE certified. NOTE: The AIR wind turbine is designed
and has proven performance in temperature ranges of -40°C to 50°C.
Model
Weight
Rotor Diameter
Start Up Wind
Kilowatt Hours/month
Max. Wind Speed
Rated Power
Certifications
AIR 30, AIR X Marine and AIR Silent X
13 lb. / 5.9 kg
46 in / 1.17 m
8 mph (3.59 m/s)
30 kWh/month @ 12 mph (5.5 m/s)
110 mph (49.2 m/s)
400 watts @ 28 mph / 12.5 m/s
CSA,
IEC &
CE
AIR 30 wind turbines are eligible to bear the CSA mark with “C” and “US”
indicators. The “C” and “US” indicators signify that the product has been
evaluated to the applicable CSA and ANSI/UL standards for use in Canada
and the US.
Voltage Regulation Set Point (factory setting)
12 Volt Systems
14.1 Volts
24 Volt Systems
28.2 Volts
48 Volt Systems
56.4 Volts
Regulator Adjustment Range
12 Volt Systems
13 to 17 volts (approximately)
24 Volt Systems
26 to 34 Volts (approximately)
48 Volt Systems
52 to 68 Volts (approximately)
Recommended Fuse Size (AIR 40 and AIR Breeze) *
TOWER LOADS: Shaft
Thrust* 80 lb. @ 100
mph wind speed (230 N @ 45 m/s)
* Install overcurrent protection in accordance with CEC and NEC.
12 Volt Systems
20 amp (slow blow)
24 Volt Systems
10 amp (slow blow)
48 Volt Systems
5 amp (slow blow)
Recommended Fuse Size (AIR 30, AIR X Marine and AIR Silent-X) *
12 Volt Systems
40 amp (slow blow)
24 Volt Systems
25 amp (slow blow)
48 Volt Systems
20 amp (slow blow)