AIR 40, AIR Breeze, AIR 30, AIR X MARINE and AIR SILENT-X are trademarks of Primus Wind Power 2013 Primus Wind Power Inc.
AIR Owner’s Manual 3-CMLT-2020-A
24
Number of
Turbines:
0-30 ft (/
0-9 m)
30ft-60ft /
(9-18 m)
60ft-90ft (/
18-27 m)
90ft-150 ft /
(27-46 m)
150ft-190ft /
(46-58 m)
190ft-250 ft/
(58-76 m)
250 ft-310 ft /
(76-95 m)
310ft-390 ft /
(95-119 m)
390ft-500ft /
(119-152 m)
1
10/6 mm
2
8/10 mm
2
4/25 mm
2
2/35 mm
2
2/35 mm
2
1/50 mm
2
0/50 mm
2
00/70 mm
2
000/95 mm
2
2
6/16 mm
2
4/25 mm
2
2/35 mm
2
0/50 mm
2
00/70 mm
2
000/95 mm
2
0000/120 mm
2
***
***
3
4/25 mm
2
2/35 mm
2
0/50 mm
2
000/95 mm
2
0000/120 mm
2
***
***
***
***
Number of
Turbines:
0-30 ft
/
(0-9 m)
30ft-60ft /
(9-18 m)
60ft-90ft /
(18-27 m)
90ft-150 ft /
(27-46 m)
150ft-190ft /
(46-58 m)
190 ft-250 ft /
(58-76 m)
250 ft-310 ft /
(76-95 m)
310ft-390 ft /
(95-119 m)
390ft-500ft /
(119-152 m)
1
14/2.5 mm
2
12/4 mm
2
10/6 mm
2
8/10 mm
2
8/10 mm
2
6/16 mm
2
6/16 mm
2
4/25 mm
2
4/25 mm
2
2
12/4 mm
2
10/6 mm
2
8/10 mm
2
6/16 mm
2
4/25 mm
2
2/35 mm
2
2/35 mm
2
1/50 mm
2
0/50 mm
2
3
10/6 mm
2
8/10 mm
2
6/16 mm
2
4/25 mm
2
2/35 mm
2
2/35 mm
2
1/50 mm
2
0/50 mm
2
00/70 mm
2
Number of
Turbines:
0-30 ft
/
(0-9 m)
30ft-60ft /
(9-18 m)
60ft-90ft /
(18-27 m)
90ft-150 ft /
(27-46 m)
150ft-190ft /
(46-58 m)
190 ft-250 ft /
(58-76 m)
250 ft-310 ft /
(76-95 m)
310ft-390 ft /
(95-119 m)
390ft-500ft /
(119-152 m)
1
14/2.5 mm
2
14/2.5 mm
2
14/2.5mm
2
14/2.5 mm
2
14/2.5 mm
2
12/4 mm
2
12/4 mm
2
10/6 mm
2
10/6 mm
2
2
14/2.5 mm
2
14/2.5 mm
2
14/2.5 mm
2
12/4 mm
2
10/6 mm
2
8/10 mm
2
8/10 mm
2
8/10 mm
2
6/16 mm
2
3
14/2.5 mm
2
14/2.5 mm
2
12/4 mm
2
10/6 mm
2
8/10 mm
2
8/10 mm
2
6/16 mm
2
6/16 mm
2
4/25 mm
2
AND AIR BREEZE
24 Volt System, AWG / Metric Wire Size
mm
2
48 Volt System, AWG / Metric Wire Size
mm
2
12 Volt System, AWG / Metric Wire Size
mm
2
Refer back to page 22 for multiple turbine install options. It is
recommended that each turbine is installed on a “home“ run
per option one for best practice installation.