HYBRID SYSTEM WIRING
Fig. 10 represents a typical “hybrid”
system with solar panels. Some charg-
ing sources (solar panels, fuel-
powered generators, additional wind
generators, etc.) connected to the
same system may interfere with the
AIR turbine’s internal charge regula-
tion process. This will not harm the
turbine, however it may spin slowly as
if “braked” or may stop completely.
Test for possible interference by dis-
connecting the other charging sources
to determine the possible cause.
Contact Primus Wind Power Customer
Service for guidance.
TIP: In this figure the AIR wind
turbine internal regulator is used.
A diversion type external regula-
tor could also have been used.
TIP: Voltage “pre-regulation” may
be prevented by increasing the
regulation set point.
WARNING: If additional sources are
connected to the same battery
bank, it is necessary to increase
battery bank size.