8.1.4
Water connections and water flow rate
Connection diameter
Recommended flow rate
Minimum flow rate
PE hoses 12 mm
7-8 l/min (ca. 1 l/(min · kW)
not lower than 5 l/min
PE hoses 16 mm
14-16 l/min
not lower than 10 l/min
Tab. 8.2:
Water connections and water flow rate
Remove the sealing plugs of the water connections
1. Push
2. Pull
Release Ring
1. Please push down the release ring of the connection
and pull out the plug with your free hand.
2. Remove the sealing plugs of the water connections and
keep it in a save place.
3. Close the flow line (Water In) and the return flow (Water
Out) of the device, by inserting the hose as far as pos-
sible (approx. 2 cm deep).
Fig. 8.2:
Remove the sealing plugs of the water connections
8.2
Compressed Air
The compressed air is required in order to generate a rotating air flow in the cyclone which is directed out-
wards. This is supposed to prevent the penetration of dirt particles.
Connect the compressed air supply by means of a plastic hose with an outer diameter of 6 mm.
Please only connect compressed air with a pressure of 0,5 bar ... 1,0 bar.
Specification of compressed air according to ISO 8573-1: 2010: 6:4:4.
Compressed Air
Supply
∅
6 mm
Fig. 8.3:
Compressed air supply (on the face side)
Содержание HP-MSM-HB
Страница 2: ......
Страница 3: ...3 Revision 00 EN 01 2021 HP MSM HB 35 0 6 IMPORTANT READ CAREFULLY BEFORE USE KEEP FOR FUTURE USE...
Страница 72: ...72 Revision 00 EN 01 2021 HP MSM HB 35 0 6 16 Accessories...
Страница 77: ...77 Revision 00 EN 01 2021 HP MSM HB 35 0 6 19 Declaration of conformity...
Страница 149: ...149 Revision 00 EN 01 2021 HP MSM HB 35 0 6...