9.45, 9.45i Treadmill
Page 17
Procedure 4.1 - Calibrating the Lift Limit Switches, 9.45 (1L)
WARNING
Always turn off the circuit breaker and unplug the treadmill before you remove the treadmill hood.
1.
If the treadmill is not already at zero percent incline, press any key when the
CALIBRATE
LIFT PRESS ANY KEY
prompt is displayed.
2.
Using the ruler, measure the distance between the floor and the top of the front and back
ends of the side rail (see Diagram 4.1).
Note:
The distance between the floor and the top of the front end of the side rail should be 9 inches.
Diagram 4.1 - Treadmill Side Rail Measurement
Содержание 9.45
Страница 55: ...9 45 9 45i Treadmill Page 55 Wiring Diagram 7 1 9 45 1L Unit...
Страница 56: ...9 45 9 45i Treadmill Page 56 Block Diagram 7 2 9 45 1L Units...
Страница 57: ...9 45 9 45i Treadmill Page 57 Wiring Diagram 7 3 9 45 2P 3Y Units...
Страница 58: ...9 45 9 45i Treadmill Page 58 Block Diagram 7 4 9 45 2P 3Y Units...