Helios Large Display Pulse Input Rate/Totalizer Instruction Manual
PD2-6300
34
Setting the Relay Operation (
relay
)
This menu is used to set up the operation of the relays.
Caution!
During setup, the relays do not follow the input
and they will remain in the state found prior to
entering the Relay menu.
1. Relay assignment
a. Rate for low and high alarm
b. Total
c. Grand total
d. Modbus input process variable
2. Relay action
a. Automatic reset only (non-
latching)
b. Aut manual reset at any
time (non-latching)
c. Latching (manual reset only)
d. Latching with Clear (manual
reset only after alarm condition
has cleared)
e. Pump alternation control
(automatic reset only)
f. Sampling (the relay is activated
for a user-specified time)
g. Off (relay state controlled by
Interlock feature)
3. Set and reset points
4. Fail-safe operation
a. On (enabled)
b. Off (disabled)
5. Time delay
a. On delay (0-999.9 seconds)
b. Off delay (0-999.9 seconds)
Relay Assignment (
Assign
)
The relays can be assigned to any of the following parameters:
1.
Rate for low or high alarm indication
2.
Total for alarm indication
3. Grand total for alarm indication
4. Modbus input
!